Lenovo ThinkSystem D2 Manual page 26

Enclosure, modular enclosure, modular enclosure for 6u configuration and thinksystem sd530 compute node messages and codes reference
Hide thumbs Also See for ThinkSystem D2:
Table of Contents

Advertisement

Severity: Critical
User Action:
Information only; no action is required.
• 086F06E0: PS1: Power Supply, Configuration error was asserted.
The installed PSU does not supported
Severity: Critical
User Action:
1. Check the PSU type of installed PSU
2. Make sure the PSU are in the support list
• 086F06E1: PS2: Power Supply, Configuration error was asserted.
The installed PSU does not supported
Severity: Critical
User Action:
1. Check the PSU type of installed PSU
2. Make sure the PSU are in the support list
• 106F0202: EvtLogDisabled: Event Logging Disabled, Log Area Reset/Cleared was asserted.
SMM system event log is cleared.
Severity: Informational
User Action:
Information only; no action is required.
• 106F0402: EvtLogDisabled: Event Logging Disabled, SEL Full was asserted.
Error is asserted when System Event Log is 100% full.
Severity: Critical
User Action:
Clear the system event log (SMM)
• 106F0502: EvtLogDisabled: Event Logging Disabled, SEL Almost Full was asserted.
Warning is asserted when system event log is at least 75% full.
Severity: Warning
User Action:
No action is required. Be aware that the system event log is almost full.
• 126F0404: System Event: System Event, PEF Action was asserted.
SMM PEF is enabled
Severity: Informational
User Action:
Information only; no action is required.
• 146F0231: SMM_RESET: Button Or Switch, Reset Button pressed was asserted.
A event indicate SMM system reboot
Severity: Informational
22
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute Node
Messages and Codes Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7x207x217x22

Table of Contents