setup, OneCLI utility, or using adapter manufacturer utilities so that adapter firmware can be
updated.)
3. Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFIO0014J: A bad option ROM checksum was detected for the device found at Bus [arg1]
Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The
physical slot number is [arg6].
Severity: Error
User Action:
Complete the following steps:
1. If thisPCIe device and/or any attached cables were recently installed, moved, serviced or upgraded.
Reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.
Note: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFIO0015I: IFM: System reset performed to reset adapters.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFIO0016M: IFM: Reset loop avoided - Multiple resets not allowed.
Severity: Warning
User Action:
Complete the following steps:
1. Update all firmware (including adapter firmware) to the latest levels.
2. If problem persists escalate to the next level of support.
• FQXSFIO0017M: IFM: Error communicating with the XCC - IFM may not be deployed correctly.
Severity: Error
User Action:
Complete the following steps:
1. Update all system firmware (including adapter firmware) to the latest levels.
Note: If the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before the update.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
164
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference