Lenovo ThinkSystem D2 Manual page 178

Enclosure, modular enclosure, modular enclosure for 6u configuration and thinksystem sd530 compute node messages and codes reference
Hide thumbs Also See for ThinkSystem D2:
Table of Contents

Advertisement

• FQXSFMA0031K: Intel Optane DCPMM [arg1] has reached 1% remaining spares block and still
functioning.
Severity: Warning
User Action:
Complete the following steps:
1. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
3. Check if the DCPMM meets warranty terms.
a. If the DCPMM meets the warranty terms, contact Lenovo Support for DCPMM replacement.
b. If the DCPMM does not meet the warranty terms, order a new comparable DCPMM through an
authorized Lenovo reseller.
4. Collect Service log and contact Lenovo support to schedule DCPMM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0032M: Intel Optane DCPMM [arg1] has no remaining spares block.
Severity: Error
User Action:
Complete the following steps:
1. Back up data.
2. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
3. Check if the DCPMM meets warranty terms.
a. If the DCPMM meets the warranty terms, contact Lenovo Support for DCPMM replacement.
b. If the DCPMM does not meet the warranty terms, order a new comparable DCPMM through an
authorized Lenovo reseller.
4. Collect Service log and contact Lenovo support to schedule DCPMM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0033M: Intel Optane DCPMM persistent memory interleave set has [arg1] DCPMMs
(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0034M logs will provide the correct location for DCPMMs.
4. Move all DCPMMs of error message FQXSFMA0034M logs to the correct location.
5. If the problem persists, collect Service Data logs.
174
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7x207x217x22

Table of Contents