Pr.
Name
349
Communication reset selection
374
Overspeed detection level
390
% setting reference frequency
414
PLC function operation selection
415
Inverter operation lock mode setting
416
Pre-scale function selection
417
Pre-scale setting value
418
Extension output terminal filter
442
Default gateway address 1
443
Default gateway address 2
444
Default gateway address 3
445
Default gateway address 4
447
Digital torque command bias
448
Digital torque command gain
450
Second applied motor
451
Second motor control method selection
453
Second motor capacity
454
Number of second motor poles
455
Second motor excitation current
456
Rated second motor voltage
457
Rated second motor frequency
458
Second motor constant (R1)
459
Second motor constant (R2)
460
Second motor constant (L1) / d-axis inductance (Ld) 3C
461
Second motor constant (L2) / q-axis inductance (Lq) 3D
462
Second motor constant (X)
463
Second motor auto tuning setting/status
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
498
PLC function flash memory clear
Communication error execution waiting
500
time
Communication error occurrence count
501
display
502
Stop mode selection at communication error
503
Maintenance timer
504
Maintenance timer warning output set time
505
Speed setting reference
506
Display estimated main circuit capacitor residual life 06
507
Display ABC relay contact life
509
Display power cycle life
541
Frequency command sign selection
542
Communication station number (CC-Link)
543
Baud rate selection (CC-Link)
544
CC-Link extended setting
547
USB communication station number
548
USB communication check time interval
549
Protocol selection
550
NET mode operation command source selection
551
PU mode operation command source selection
Instruction
*1
code
31
B1
3
4A
CA
3
×
×
5A
DA
3
0E
8E
4
0F
8F
4
10
90
4
11
91
4
12
92
4
2A
AA
4
2B
AB
4
2C
AC
4
2D
AD
4
2F
AF
4
×
×
30
B0
4
×
×
32
B2
4
33
B3
4
35
B5
4
×
36
B6
4
37
B7
4
38
B8
4
×
39
B9
4
×
3A
BA
4
×
3B
BB
4
×
BC
4
×
BD
4
×
3E
BE
4
×
3F
BF
4
×
5F
DF
4
60
E0
4
61
E1
4
62
E2
4
00
80
5
01
81
5
02
82
5
03
83
5
04
84
5
05
85
5
86
5
07
87
5
09
89
5
29
A9
5
2A
AA
5
2B
AB
5
2C
AC
5
2F
AF
5
30
B0
5
31
B1
5
32
B2
5
33
B3
5
17.3 Parameters (functions) and instruction codes under different control methods
*2
Control method
Sensorless
Sensorless
Sensorless
PM
PM
PM
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Parameter
11
12
*4
*4
13
×
×
14
×
*4
*4
15
*4
*4
*4
*4
*4
*4
16
17
×
18
×
19
×
×
×
×
20
×
×
×
×
×
×
×
×
×
×
×
×
×
×
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
421