15
(G) Control Parameters
Purpose
To set the starting torque manually
To set the motor constant
To select the V/F pattern matching the
application
To perform energy saving operation
To compensate the motor slip amount when
replacing an SF-JR motor with an SF-PR
motor
To adjust the motor braking torque
To coast the motor to a stop
To use the regeneration unit to increase the
motor braking torque
To avoid overvoltage fault due to
regenerative driving by automatic
adjustment of output frequency
To select the control method
To secure the low-speed torque by
compensating the slip of the motor
To select the torque characteristic
To adjust the speed control gain
To adjust the torque control gain
To perform frequency control appropriate for
load torque
To suppress the machine resonance
To adjust the speed gain for Advanced
magnetic flux vector control
15.1

Manual torque boost

V/F
V/F
V/F
Voltage drop in the low-frequency range can be compensated, improving reduction of the motor torque in the low-speed range.
• Motor torque in the low-frequency range can be adjusted according to the load, increasing the motor torque at the start up.
• By using the RT signal, it is possible to switch between 2 types of torque boost.
Pr.
0
Torque boost
G000
46
Second torque boost
G010
384
15.(G) Control Parameters
15.1 Manual torque boost
Manual torque boost
Base frequency, base frequency
voltage
Load pattern selection
Energy saving operation
SF-PR slip amount adjustment
mode
DC injection brake and zero
speed control
Selection of motor stop method
Regenerative brake selection
Regeneration avoidance function
Control method selection
Slip compensation
Constant output range torque
characteristic selection
Speed control gain
Torque control gain
Droop control
Speed smoothing control
Speed control gain
Name
Initial value
*1
2% to 6%
9999
Parameter to set
P.G000, P.G010
P.G001, P.G002,
P.G011
P.G003
P.G030
P.G060, P.G061
P.G100, P.G101,
P.G103, P.G110
P.G106
P.E300, P.G107,
P.T720
P.G120, P.G121,
P.G123 to P.G125
P.G200, P.G300
P.G203 to P.G205 Pr.245 to Pr.247
P.G210
P.G211, P.G212,
P.G311, P.G312
P.G213, P.G214,
P.G313, P.G314
P.G400, P.G401
P.G410, P.G411
P.G932, P.G942
Setting range
0% to 30%
Set the output voltage at 0 Hz in %.
0% to 30%
Set the torque boost value at when the RT signal is ON.
9999
Without the second torque boost
Refer to
page
Pr.0, Pr.46
384
Pr.3, Pr.19, Pr.47
386
Pr.14
388
Pr.60
390
Pr.673, Pr.674
391
Pr.10 to Pr.12,
392
Pr.850
Pr.250
394
Pr.17, Pr.30, Pr.70
396
Pr.882, Pr.883,
Pr.885, Pr.886,
400
Pr.665
Pr.800, Pr.451
88
403
Pr.803
102,
Pr.820, Pr.821,
109
Pr.830, Pr.831
Pr.824, P.825,
124
Pr.834, P.835
Pr.286, Pr.287
404
Pr.653, Pr.654
405
Pr.89, Pr.569
92
Description
119