Install The Connector And Connector Mount Bracket - Toro TX 1000 Operator's Manual

Compact tool carrier, 4-in-1 electric/hydraulic bucket
Table of Contents

Advertisement

2.
Park the machine on a level surface, engage the
parking brake and lower the arms.
3.
Shut off the engine, remove the key and allow
the engine to cool.
4.
Turn the battery-disconnect switch to the off
position; refer to your machine Operator's
Manual.
5.
If your machine does not have a
battery-disconnect switch, disconnect the
negative (black) cable from the battery, then
disconnect the positive (red) cable
Figure 4
WARNING
Incorrect battery cable routing could
damage the machine and cables, causing
sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
• Always disconnect the negative
(black) battery cable before
disconnecting the positive (red)
cable.
• Always connect the positive (red)
battery cable before connecting the
negative (black) cable.
2
Install the Connector and
Connector Mount Bracket
Parts needed for this procedure:
1
(Figure
4).
1
2
2
2
Procedure
1.
g029753
2.
1. Hose fitting
2. Bulkhead coupler threads
3.
4.
7
Connector mount bracket
7-pin connector
Bolt (5/32 inches)
Spacer
Nut (5/32 inches)
Release any built up hydraulic pressure by
moving the auxiliary hydraulics lever forward
and backward a few times.
Disconnect the right side outer hose fitting
(1–1/8 inches) from the bulkhead coupler and
plug the hose end.
Figure 5
Remove the bulkhead coupler locknut (1–5/16
inches).
Align the connector mount bracket over the
threaded end of the bulkhead coupler and
secure it with the bulkhead coupler locknut.
g242258
3. Bulkhead coupler locknut