Mitsubishi Electric MELSEC-Q Structured Programming Manual page 240

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
• FX
/FX
/FX
3S
3G
Number
1st analog special adapter
M 8280
Ch1: Input mode switching
M 8281
Ch2: Input mode switching
M 8282
Ch3: Input mode switching
M 8283
Ch4: Input mode switching
M 8284
Not used (disabled)
M 8285
Not used (disabled)
M 8286
Not used (disabled)
M 8287
Not used (disabled)
M 8288
Not used (disabled)
M 8289
Not used (disabled)
2nd analog special adapter
M 8290
Ch1: Input mode switching
M 8291
Ch2: Input mode switching
M 8292
Ch3: Input mode switching
M 8293
Ch4: Input mode switching
M 8294
Not used (disabled)
M 8295
Not used (disabled)
M 8296
Not used (disabled)
M 8297
Not used (disabled)
M 8298
Not used (disabled)
M 8299
Not used (disabled)
Number
FX
1st analog special adapter
M 8280
Temperature unit selection
M 8281
Not used
M 8282
Not used
M 8283
Not used
M 8284
Not used
M 8285
Not used
M 8286
Not used
M 8287
Not used
M 8288
Not used
M 8289
Not used
2nd analog special adapter
M 8290
Temperature unit selection
M 8291
Not used
M 8292
Not used
M 8293
Not used
M 8294
Not used
M 8295
Not used
M 8296
Not used
M 8297
Not used
M 8298
Not used
M 8299
Not used
*1.
In the case of FX
*2.
Can be connected only to 40-point or 60-point type FX
238
PLCs
3GC
FX
-4AD-ADP
3U
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
*2
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
Operation and function
-4AD-PT(W)-ADP
FX
3U
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
*2
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
PLC, versions 1.20 or later are applicable.
3G
4 Operations of Special Devices (M8000 and later, D8000 and later)
4.2 Supplement of Special Devices (M8000 and later and D8000 and later)
Operation and function
FX
-4DA-ADP
3U
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.
-4AD-TC-ADP
FX
3U
3U
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
and FX
3G
*1
FX
3U
-3A-ADP
-4AD-PNK-ADP
PLCs.
3GC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-lMelsec-fFx3sFx3gFx3gcFx3u ... Show all

Table of Contents