Mitsubishi Electric MELSEC-Q Structured Programming Manual page 152

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
Number and name
Timing clock and positioning (Refer to the position control manual for details.)
[M]8330
DUTY instruction: Timing clock output 1
[M]8331
DUTY instruction: Timing clock output 2
[M]8332
DUTY instruction: Timing clock output 3
[M]8333
DUTY instruction: Timing clock output 4
[M]8334
DUTY instruction: Timing clock output 5
[M]8335
Unavailable
*2
DVIT instruction: Interrupt input specification function enable
M 8336
[M]8337
Unavailable
[M]8338
PLSV instruction: Acceleration/deceleration operation
[M]8339
Unavailable
[M]8340
[Y000] Pulse output monitor (ON:BUSY/OFF:READY)
*2
[Y000] Clear signal output function enable
M 8341
*2
[Y000] Zero point return direction specification
M 8342
M 8343
[Y000] Normal rotation limit
M 8344
[Y000] Reverse rotation limit
*2
[Y000] Near-point watchdog signal logic reverse
M 8345
*2
[Y000] Zero point signal logic reverse
M 8346
*2
[Y000] Interrupt signal logic reverse
M 8347
[M]8348
[Y000] Positioning instruction being driven
*2
[Y000] Pulse output stop command
M 8349
[M]8350
[Y001] Pulse output monitor (ON:BUSY/OFF:READY)
*2
[Y001] Clear signal output function enable
M 8351
*2
[Y001] Zero point return direction specification
M 8352
M 8353
[Y001] Normal rotation limit
M 8354
[Y001] Reverse rotation limit
*2
[Y001] Near-point watchdog signal logic reverse
M 8355
*2
[Y001] Zero point signal logic reverse
M 8356
*2
[Y001] Interrupt signal logic reverse
M 8357
[M]8358
[Y001] Positioning instruction being driven
*2
[Y001] Pulse output stop command
M 8359
[M]8360
[Y002] Pulse output monitor (ON:BUSY/OFF:READY)
*2
[Y002] Clear signal output function enable
M 8361
*2
[Y002] Zero point return direction specification
M 8362
M 8363
[Y002] Normal rotation limit
M 8364
[Y002] Reverse rotation limit
*2
[Y002] Near-point watchdog signal logic reverse
M 8365
*2
[Y002] Zero point signal logic reverse
M 8366
*2
[Y002] Interrupt signal logic reverse
M 8367
[M]8368
[Y002] Positioning instruction being driven
*2
[Y002] Pulse output stop command
M 8369
*1.
Available in Ver. 2.20 or later.
*2.
Cleared when the PLC mode switches from RUN to STOP.
*3.
Available in Ver. 1.30 or later.
150
4 Operations of Special Devices (M8000 and later, D8000 and later)
Operation and function
4.1 Special Device List (M8000 and later, D8000 and later)
Applicable model
FX
FX
FX
FX
3U
3UC
3G
*1
-
*1
-
*1
-
*1
-
*1
-
-
-
-
*3
-
-
-
-
*1
-
-
-
-
-
-
Corresponding
FX
3GC
3S
special device
-
-
D8330
-
-
D8331
-
-
D8332
-
-
D8333
-
-
D8334
-
-
-
-
-
D8336
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-lMelsec-fFx3sFx3gFx3gcFx3u ... Show all