The output signals must meet the following requirements:
l
l
l
Issue 13 (2009-12-30)
Current type
When moving objects are not detected, the output current should be less than 200 uA.
–
When moving objects are detected, the output current should be greater than 1 mA.
–
Voltage type
When moving objects are not detected, the output voltage should be less than 3.3 V.
–
When moving objects are detected, the output voltage should be greater than 5 V.
–
Dry contact point type
When moving objects are detected, the sensor should be disconnected.
–
When moving objects are detected, the sensor should be connected.
–
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Introduction to the Sensors
3-11