Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to the chart below
for a description of each option, its range and default setting.
Input Data
Trunk Port Number
Prog. No.
14-01-01
Trunk Name
Set the names for trunks. The trunk
name displays at display keysets
for incoming and outgoing calls.
14-01-02
Transmit CODEC Gain Type
Use this option to select the
CODEC gain for the trunk.
The option sets the amount of gain
(signal amplification) for the trunk
you are programming.
14-01-03
Receive CODEC Gain Type
Use this option to select the
CODEC gain for the trunk.
The option sets the amount of gain
(signal amplification) for the trunk
you are programming.
14-01-04
Transmit Gain Level for
Conference and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an
Unsupervised Conference.
14-01-05
Receive Gain Level for
Conference and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an
Unsupervised Conference.
14-01-06
SMDR Print Out
Use this option to have the system
include/exclude the trunk you are
programming form the SMDR
printout. See Program 35-01 and
35-02 for SMDR printout options.
14-01-07
Outgoing Calls
Use this option to allow/prevent
outgoing calls on the trunk you are
programming.
Program 14: Trunk Basic Setup
14-01: Basic Trunk Data Setup
Item
Up to 12 Characters
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
0 : No Printout
1 : Printout
0 : Prevented
1 : Allowed
Input data
83
1-51
Default
Related Program
Refer
below
32
(0 dB)
32
(0 dB)
22
(-5dB)
22
(-5dB)
1
1