Program 11: System Configuration Setup
11-01: System Numbering
Step 3: Assign a function to the code selected
After entering a code and specifying its length, you must assign its function. This is the Dial Type column in the
System Numbering (page 52) table. The choices are:
Dial Types
Dial Type Description
0
-Not Used-
1
Service Code
2
Extension Number
3
Trunk Access Number
4
Special Trunk Access
5
Operator Access
6
ARS/F-Route Access
Changing the Dial Type for a range of codes can have a dramatic affect on how your system operates. Assume,
l
for example, the site is a hotel that has room numbers from 100-399. In order to make extension numbers correspond
to room numbers, you should:
- In Program 11-02, reassign extension numbers on each floor from 100 to 399.(Other applications might also
require you to change entries in Program 11-10 through 11-16.)
System Numbering table;
Dialed Number
1st figure
2
nd
figure
1
1x
11-1#
2
2x
21-2#
3
3x
31-3#
4
4x
41-4#
5
5x
51-5#
6
6x
61-6#
7
7x
71-7#
8
8x
81-8#
9
9x
91-9#
0
0x
01-0#
*
*x
*1-*#
#
#x
#1-##
Programming Manual
11-10: Service Code Setup(for System Administrator)
11-11: Service Code Setup(for Setup/Entry)
11-12: Service Code Setup(for Service Access)
11-15: Service Code Setup(for Special Access)
11-02: Extension Number
11-04: Virtual Extension Number
11-06: ACI Extension Numbering
11-07: Department Calling Group Numbers
11-08: ACI Group Pilot Number
11-09: Trunk Access Code
11-09: Trunk Access Code
20-17: Operator's Extension
44-xx
Number of digits
3
2 (Extension access)
0
0 (Not Used)
3
2 (Extension access)
0
0 (Not Used)
3
2 (Extension access)
0
0 (Not Used)
3
2 (Extension access)
0
0 (Not Used)
3
2 (Extension access)
0
0 (Not Used)
3
2 (Extension access)
0
0 (Not Used)
3
1 (Service code access)
0
0 (Not used)
3
1 (Service code access)
0
0 (Not used)
1
3 (Trunk access)
0
0 (Not used)
1
5 (Operator access)
0
0 (Not used)
4
1 (Service code access)
0
0 (Not used)
4
1 (Service code access)
0
0 (Not used)
44
Related Program
Dial Type(Default)
IN
SA
SB
Input data
0 : Not used
1 : Service Code
Access
2 : Extension
Access
3 : Trunk Access
4 : Special Trunk
Access
5 : Operator Access
6 : Flexible Routing
Access