7. When the code type is GS1 DataBar Stacked/GS1 DataBar Limited
When the code type is GS1 DataBar Stacked CC-A/GS1 DataBar Limited CC-A and specify its 1D side
settings
Name
Omit
Object No.
X-position
Y
Y-position
Y
Rotation angle
Y
Code type
(Y)
Module width
Y
Bar code height to
module width ratio
or
Y
Lower barcode
height to module
width ratio
Separator height to
Y
module width ratio
Invert
Y
Left guard width to
Y
module width ratio
Right guard width
to module width
Y
ratio
Human readable
Y
text
Code marking
Y
direction
Laser power
Y
correction
Scan speed
Y
correction
Laser power
correction to
Y
separator
Scan speed
correction to
Y
separator
Total data length
* Setting request data are variable length.
Data
length
Data contents
[byte]
Max. 4*
"0000"–"1999"
Max. 8*
"-999.999"–"+999.999" [mm]
Max. 8*
Max. 8*
"-180.000"–"+180.000" [°]
"31": GS1 DataBar Stacked
"33": GS1 DataBar Limited
2
"41": GS1 DataBar Stacked CC-A
"43": GS1 DataBar Limited CC-A
Max. 5*
"0.050"–"1.000" [mm]
Max. 6*
"001.00"–"100.00"
Max. 4*
"00.0"–"10.0"
"0": Do not invert
1
"1": Invert
Max. 4*
"01.0"–"20.0"
Max. 4*
"0": OFF
1
"1": ON
"0": One-way direction
1
"1": Alternate
Max. 3*
"000"–"999" [%]
Max. 3*
"001"–"999" [%]
Max. 3*
"000"–"999" [%]
Max. 3*
"001"–"999" [%]
Max. 84
It is the length including the separator ",".
ME-LPGS-SR-5
Remarks
• It is the center coordinate of the code.
• The rotation center is the center of the
code symbol.
• For the composite codes, these settings
are applied to both 1D and 2D side.
For the composite codes, this setting is
applied to both 1D and 2D side.
Specify a larger value than the line width in
the object group settings.
• Specifies the ratio of the code height to
module width.
• For GS1 DataBar Stacked (CC-A), it
specifies the height ratio of the lower
side.
• Only when code type is set to GS1
DataBar Stacked (CC-A), set the value.
For other codes, omit this setting.
• Specifies the ratio of GS1 DataBar
Stacked separator to module width.
Set "0" to mark a bar, "1" to mark a space.
Specifies the ratio of guard pattern width
to module width.
The correction ratio is calculated using the
value set at the laser settings as 100%.
• Only when the code type is set to GS1
DataBar Stacked (CC-A), set the value.
For other codes, omit these settings.
• The correction ratio is calculated using
the value set at the laser settings as
100%.