ABB Relion 670 Series Product Manual page 154

Generator protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Generator protection REG670
Version 2.2
Binary input/output modules
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1BIM and 1 BOM required in slots P3 and P4.
Slot position (front/rear
view)
1/2 Case with 1 TRM
3/4 Case with 2 TRM
1/1 Case with 2 TRM
Compression terminals
No board in slot
Binary output module 24
output relays (BOM)
BIM 16 inputs, RL24,
24-30VDC, 50mA
BIM 16 inputs, RL48,
48-60VDC, 50mA
BIM 16 inputs, RL110,
110-125VDC, 50mA
BIM 16 inputs, RL220,
220-250VDC, 50mA
BIM 16 inputs, RL220,
220-250VDC, 120mA
BIM 16 inputs, RL24,
24-30VDC, 50mA, enhanced
pulse counting
BIM 16 inputs, RL48,
48-60VDC, 50mA, enhanced
pulse counting
BIM 16 inputs, RL110,
110-125VDC, 50mA,
enhanced pulse counting
BIM 16 inputs, RL220,
220-250VDC, 50mA,
enhanced pulse counting
IOM 8 inputs, RL 24-30 VDC,
50mA, 10+2 output relays
IOM 8 inputs, RL 48-60 VDC,
50mA, 10+2 output relays
IOM 8 inputs, RL 110-125
VDC, 50mA, 10+2 output
relays
IOM 8 inputs, RL 220-250
VDC, 50mA, 10+2 output
relays
IOM 8 inputs, RL 220-250
VDC, 110mA, 10+2 output
relays
IOM with MOV 8 inputs, RL
24-30 VDC, 50mA, 10+2
output relays
IOM with MOV 8 inputs, RL
48-60 VDC, 50mA, 10+2
output relays
IOM with MOV 8 inputs, RL
110-125 VDC, 50mA, 10+2
output relays
IOM with MOV 8 inputs, RL
220-250 VDC, 50mA, 10+2
output relays
mA input module MIM 6
channels
SOM static output module, 6
heavy duty static outputs,
250 VDC + 6 output relays
154
Ordering no
1MRK002960-KA
C
1MRK000614-AB
A
1MRK000508-DD
B1
1MRK000508-AD
C1
1MRK000508-BD
D1
1MRK000508-CD
E1
1MRK000508-CE
E2
1MRK000508-HA
1MRK000508-EA
1MRK000508-FA
1MRK000508-GA
1MRK000173-GD
1MRK000173-AE
1MRK000173-BE
1MRK000173-CE
1MRK000173-CF
1MRK000173-GC
1MRK000173-AD
1MRK000173-BD
1MRK000173-CD
1MRK000284-AB
1MRK002614-CA
Selection for
C
position #10
© Copyright 2017 Hitachi Power Grids. All rights reserved
#10
X
X
X
X
X
A
A
A
A
A
B1
B1
B1
B1
B1
C1
C1
C1
C1
C1
D1
D1
D1
D1
D1
E1
E1
E1
E1
E1
E2
E2
E2
E2
E2
F
F
F
F
F
G
G
G
G
G
H
H
H
H
H
K
K
K
K
K
L1
L1
L1
L1
L1
M1
M1
M1
M1
M1
N1
N1
N1
N1
N1
P1
P1
P1
P1
P1
P2
P2
P2
P2
P2
U
U
U
U
U
V
V
V
V
V
W
W
W
W
W
Y
Y
Y
Y
Y
R
R
R
R
R
T2
T2
T2
T2
T2
1MRK 502 074-BEN M
Notes and rules
1)
2)
Only for B30/C30
3)
X
X
X
X
A
A
A
A
4)
B1
B1
B1
B1
C1
C1
C1
C1
D1
D1
D1
D1
E1
E1
E1
E1
E2
E2
E2
E2
F
F
F
F
G
G
G
G
H
H
H
H
K
K
K
K
L1
L1
L1
L1
M1
M1
M1
M1
N1
N1
N1
N1
P1
P1
P1
P1
P2
P2
P2
P2
U
U
U
U
V
V
V
V
W
W
W
W
Y
Y
Y
Y
R
R
R
R
5)
T2
T2
T2
6)
Hitachi Power Grids

Hide quick links:

Advertisement

Table of Contents
loading