Generator protection REG670
Version 2.2
Software options
No option
Restricted earth fault protection, low impedance
High impedance differential protection - 3 blocks
Transformer differential protection - 2 winding
Transformer differential protection - 2 and 3 winding
Out-of-step protection
Rotor Fault Detection by Injection
Stator Fault Detection by Injection
Sensitive directional residual overcurrent and power protection
Voltage restrained overcurrent protection
Rotor overload protection
Four step directional negative phase sequence overcurrent protection - 1 block
Four step directional negative phase sequence overcurrent protection - 2 blocks
Average power transient earth fault protection
100% Stator E/F 3rd harmonic
Frequency time accumulation protection
Fuse failure supervision based on voltage difference
Control functionality for up to 30 objects
Transformer insulation loss of life monitoring
Through fault monitoring
Harmonic monitoring
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
IEC 61850-9-2 Process Bus communication, 8 merging units
Synchrophasor report, 16 phasors
1)
All fields in the ordering form do not need to be filled in.
2)
A01 only for B30
3)
A02 only for A20
4)
A31 only for A20
5)
A33 only for B30
6)
C41 only for A20
7)
C42 only for B30/C30
8)
D21 only for A20
9)
M21 only for B30/C30
10) Options P23 and P24 require two SFPs placed in pairs.
11)
This functionality requires accurate time synchronization, therefore either 'Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Language
First local HMI user dialogue language
HMI language, English IEC
Additional local HMI user dialogue language
No additional HMI language
HMI language, English US
1)
Additional 2nd languages are continuously being added. Please get in touch with local ABB sales contact.
Casing
1/2 x 19" rack casing, 1 TRM
3/4 x 19" rack casing, 2 TRM
1/1 x 19" rack casing, 2 TRM
1)
Only for A20
2)
Only for B30/C30
Hitachi Power Grids
© Copyright 2017 Hitachi Power Grids. All rights reserved
Ordering no
#3
X00
1MRK004001-AA
A01
1MRK004001-AB
A02
1MRK004001-AP
A31
1MRK004001-AR
A33
1MRK004001-BW
B22
1MRK004001-BV
B31
1MRK004001-BX
B32
1MRK004001-CT
C16
1MRK004001-UN
C36
1MRK004001-UR
C38
1MRK004001-UH
C41
1MRK004001-UK
C42
1MRK004001-UY
C54
1MRK004001-DE
D21
1MRK004001-EC
E03
1MRK004001-HC
G03
1MRK004001-GZ
H39
1MRK004001-KM
M21
1MRK004001-KR
M22
1MRK004001-KS
M23
1MRK004001-PP
P23
1MRK004001-PR
P24
1MRK004001-PT
P30
1MRK004001-PX
P34
Selection for
position #3
Ordering no
#4
1MRK002930-AA
B1
X0
1MRK002920-UB
A12
Selection for
B1
position #4
Ordering no
#5
1MRK000151-VA
A
1MRK000151-VE
C
1MRK000151-VD
E
Selection for
position #5
1MRK 502 074-BEN M
Notes and rules
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
Notes and rules
1)
Notes and rules
1)
2)