ABB Relion 670 Series Product Manual page 145

Generator protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Generator protection REG670
Version 2.2
Table 228. Analog system selection
Analog system
When more than one TRM is selected, the connector type on both TRMs must be the same (A compression or B ring lug).
Slot position (front view/rear view)
No Transformer input module included
TRM 12I 1A, 50/60Hz, compression terminals
TRM 12I 5A, 50/60Hz, compression terminals
TRM 9I 1A + 3U 110/220V, 50/60Hz, compression terminals
TRM 9I 5A + 3U 110/220V, 50/60Hz, compression terminals
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, compression terminals
TRM 6I 1A + 6U 110/220V, 50/60Hz, compression terminals
TRM 6I 5A + 6U 110/220V, 50/60Hz, compression terminals
TRM 6I 1A, 50/60Hz, compression terminals
TRM 6I 5A, 50/60Hz, compression terminals
TRM 7I 1A + 5U 110/220V, 50/60Hz, compression terminals
TRM 7I 5A + 5U 110/220V, 50/60Hz, compression terminals
TRM 6I 5A + 1I 1A + 5U 110/220V, 50/60Hz, compression terminals
TRM 3I 5A + 4I 1A + 5U 110/220V, 50/60Hz, compression terminals
TRM 3I 5A + 3I 1A + 6U 110/220V, 50/60Hz, compression terminals
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, compression terminals
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, compression terminals
TRM 10I 1A + 2U 110/220V, 50/60Hz, compression terminals
TRM 10I 5A + 2U 110/220V, 50/60Hz, compression terminals
TRM 12I 1A, 50/60Hz, ring lug terminals
TRM 12I 5A, 50/60Hz, ring lug terminals
TRM 9I 1A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 9I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 1A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 5A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 1A, 50/60Hz, ring lug terminals
TRM 6I 5A, 50/60Hz, ring lug terminals
TRM 7I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 7I 5A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 5A + 1I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 3I 5A + 4I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 3I 5A + 3I 1A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 10I 1A + 2U 110/220V, 50/60Hz, ring lug terminals
TRM 10I 5A + 2U 110/220V, 50/60Hz, ring lug terminals
1)
Only valid if IEC 61850-9-2 Process bus communication is selected.
2)
Maximum qty=1
3)
Maximum qty=1
4)
Maximum qty=1
5)
Maximum qty=1
Hitachi Power Grids
© Copyright 2017 Hitachi Power Grids. All rights reserved
Ordering no
Selection
X0
X0
1MRK002247-CG
A1
A1
1MRK002247-CH
A2
A2
1MRK002247-BG
A3
A3
1MRK002247-BH
A4
A4
1MRK002247-BK
A5
A5
1MRK002247-AG
A6
A6
1MRK002247-AH
A7
A7
1MRK002247-DG
A8
A8
1MRK002247-DH
A9
A9
1MRK002247-AP
A12
A12
1MRK002247-AR
A13
A13
1MRK002247-AU
A14
A14
1MRK002247-AV
A15
A15
1MRK002247-AE
A16
A16
1MRK002247-EA
A17
A17
1MRK002247-EB
A18
A18
1MRK002247-FA
A19
A19
1MRK002247-FB
A20
A20
1MRK002247-CC
B1
B1
1MRK002247-CD
B2
B2
1MRK002247-BC
B3
B3
1MRK002247-BD
B4
B4
1MRK002247-BF
B5
B5
1MRK002247-AC
B6
B6
1MRK002247-AD
B7
B7
1MRK002247-DC
B8
B8
1MRK002247-DD
B9
B9
1MRK002247-AS
B12
B12
1MRK002247-AT
B13
B13
1MRK002247-AX
B14
B14
1MRK002247-AY
B15
B15
1MRK002247-AF
B16
B16
1MRK002247-EC
B17
B17
1MRK002247-ED
B18
B18
1MRK002247-FC
B19
B19
1MRK002247-FD
B20
B20
Selected
1MRK 502 074-BEN M
Notes and rules
1)
2)
3)
4)
5)
145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents