Mitsubishi Electric MELSEC iQ-R Series User Manual page 110

Channel isolated thermocouple input module/channel isolated rtd input module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address
Decimal (hexadecimal)
CH1
CH2
CH3
4132
4134
4136
(1024H)
(1026H)
(1028H)
4133
4135
4137
(1025H)
(1027H)
(1029H)
4148 to 9999
(1034H to 270FH)
■Logging data (Un\G10000 to Un\G17999)
Address
Decimal (hexadecimal)
CH1
CH2
CH3
10000
11000
12000
to
to
to
10999
11999
12999
(2710H
(2AF8H
(2EE0H
to
to
to
2AF7H)
2EDFH)
32C7H)
In Q compatible mode
Address
Decimal (hexadecimal)
CH1
CH2
CH3
0 (0H)
1
2
3
(1H)
(2H)
(3H)
9 (9H)
10 (AH)
11
12
13
(BH)
(CH)
(DH)
19 (13H)
20 (14H)
22 (16H)
23 (17H)
24 (18H)
26 (1AH)
27 (1BH)
28
30
32
(1CH)
(1EH)
(20H)
29
31
33
(1DH)
(1FH)
(21H)
44 (2CH)
45 (2DH)
APPX
108
Appendix 3 Buffer Memory Areas
CH4
CH5
CH6
4138
4140
4142
(102AH)
(102CH)
(102EH)
4139
4141
4143
(102BH)
(102DH)
(102FH)
CH4
CH5
CH6
13000
14000
15000
to
to
to
13999
14999
15999
(32C8H
(36B0H
(3A98H
to
to
to
36AFH)
3A97H)
3E7FH)
CH4
CH5
CH6
4
5
6
(4H)
(5H)
(6H)
14
15
16
(EH)
(FH)
(10H)
21 (15H)
25 (19H)
34
36
38
(22H)
(24H)
(26H)
35
37
39
(23H)
(25H)
(27H)
Name
CH7
CH8
4144
4146
CH Offset/gain setting mode
(1030H)
(1032H)
(offset specification)
4145
4147
CH Offset/gain setting mode
(1031H)
(1033H)
(gain specification)
System area
Name
CH7
CH8
16000
17000
CH Logging data
to
to
16999
17999
(3E80H
(4268H
to
to
4267H)
464FH)
Name
CH7
CH8
Conversion enable/disable
setting
7
8
CH Time average/Count
(7H)
(8H)
average/Moving average/
Primary delay filter constant
setting
System area
Conversion completed flag
17
18
CH Measured temperature
(11H)
(12H)
value
Latest error code
Range setting monitor
(Thermocouple type)
(for the thermocouple input
module)
Range setting monitor
(Resistance temperature
detector type)
(for the RTD input module)
Range setting monitor (offset/
gain setting)
System area
Averaging process setting
Offset/gain setting mode (offset
specification)
Offset/gain setting mode (gain
specification)
40
42
CH Offset temperature setting
(28H)
(2AH)
value
41
43
CH Gain temperature setting
(29H)
(2BH)
value
System area
Cold junction compensation
setting status
Default
value
0
0
Default
value
0
Default
value
00FFH
0
0
0
0
0000H
0000H
0
0
0
0
0
0
*1
Data
Auto
type
refresh
Setting
Setting
Data
Auto
type
refresh
Monitor
Data
Auto
type
refresh
Setting
Setting
Monitor
Monitor
Monitor
Monitor
Monitor
Setting
Setting
Setting
Setting
Setting
Monitor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60td8-gR60rd8-g

Table of Contents