[Caution] Adjusting side registration changes the position of the deck cover. Adjust the position of the deck cover and the cassette pull-in as needed.
b-3)Set 13x19 paper in the relevant deck and output with the setting below to confirm that the symptom does not occur.
-Service Mode > Mode List > COPIER > TEST > PG > TYPE > "5"
-Service Mode > Mode List > COPIER > TEST > PG > Set M of "COLOR-x" to "1" and set Y, C and K to "0".
-Service Mode > Mode List > COPIER > TEST > PG > In "PG-PICK", set the upper deck to "17", the middle deck to "18" and the lower deck to "19".
b-4)Service Mode > Mode List > COPIER > Option > FEED-SW > Revert CIS-OFF back to "0".
c)When POD DECK LITE-B1 is used
c-1) Service Mode > Mode List > COPIER > Option > FEED-SW > Set CIS-OFF to "1". ("0" by default)
c-2) Loosen the 4 screws [a] of the deck and adjust the image margin at the right/left sides within 2.5 divisions (1 division: 1mm).
When the symptom occurs at the front side, move the parts on both right/left sides [b] toward the front [c] to lessen the image margin at the front side.
When the symptom occurs at the rear side, move the parts on both right/left sides [b] toward the rear [d] to lessen the image margin at the rear side.
[Caution] Adjusting side registration changes the position of the deck cover. Adjust the position of the deck cover and the cassette pull-in as needed.
c-3) Set 13x19 paper in the relevant deck and output with the setting below to confirm that the symptom does not occur.
-Service Mode > Mode List > COPIER > TEST > PG > TYPE > "5"
-Service Mode > Mode List > COPIER > TEST > PG > Set M of "COLOR-x" to "1" and set Y, C and K to "0".
-Service Mode > Mode List > COPIER > TEST > PG > PG-PICK > "7"
c-4) Service Mode > Mode List > COPIER > Option > FEED-SW > Revert CIS-OFF back to "0".
B)Change the settings of adjust image quality
B-1)Have the customer log in to System Management Mode in user mode.
B-2)Select Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > In "Auto Correct Color Mismatch" select the color to which the symptom
occurs, push "+" button twice, confirm that the correction value [a] is set to "2" and push "OK".