1. OVERVIEW OF MIGRATION FROM Q17nCPUN(-T) TO RnMTCPU

1.4.5 Configuration when the MR-MV200 optical hub unit is used

The MR-MV200 can branch a single SSCNETIII/H network line in three separate directions (three
outputs per one input).
A connection example when using the MR-MV200 and the specifications are shown below.
Input voltage [V]
Consumption current [A]
Mass [kg]
Mounting method
Cable length [m]
Number of optical hub units
Number of servo amplifiers
Exterior dimensions [mm]
Line topology
Item
Cascade topology
21.6 to 26.4 VDC (24 VDC ± 10 %)
Directly mounted to the control panel or with DIN rail
Up to 16 units/line
Up to 16 axes/line
168 (H) x 30 (W) x 100 (D)
1 - 13
Star topology
Description
0.2
0.22
Up to 100