Operation
This information is unique to ACH580 input disconnect configurations (PCR or PDR).
Refer to the
Input disconnect configuration
The ACH580-31 with input disconnect is an ACH580-31 AC adjustable frequency
drive packaged with an input disconnect switch or circuit breaker, and with a door
interlocked, external operating handle. The operating handle can be padlocked in
the OFF position (padlock not supplied). Enclosure options are UL Type 1 and UL
Type 12 (NEMA 1 and NEMA 12).
The following is a typical power diagram.
The following shows the front view of the ACH580 Box Packaged Drive
configurations and identifies the major components.
ACH580-3PCR/3PDR
ACH580 Ultra-Low Harmonic Drives Installation, Operation and Maintenance Manual
Operation
instructions on page
Disconnect Switch
or Circuit Breaker
3 Phase
Input Power
3
Drive Input
Fuse
Drive Control
Panel
WARNING
RISK OF FIRE OR ELECTRIC SHOCK-
The opening of the branch-circuit protective device may
be and indication that a fault current has been
interrupted. All current-carrying parts and other
components protected by this device should be
examined and replaced if damaged. If burnout of a
current element of an overload relay occurs, the
complete overload relay must be replaced.
Operating Handle for
!
WARNING
Wait at least 5 minutes after disconnecting
supply before continuing to work.
Consult the Installation & Start-Up Manual
before working on the frequency converter.
!
ATTENTION!
Disconnect or Circuit
Attendre au moins 5 min apres sectionnement
de l'alimntation pour travailler sur l'appareil.
Consulter le Manuel d'installation et de mise
end route avant d'intervenir sur le convertisseur
de frequence.
Breaker Switch
CAUTION
VOLTAGE MAY BE PRESENT FROM MORE
THAN ONE SOURCE AND SHOULD BE
DISCONNECTED FOR SERVICING.
ATTENTION
PEUT ETRE SOUS TENSION DE PLUS D'UNE
SOURCE D'ALIMENT ELECTRIQUE. COUPER TOUTES LES
SOURCES D'ALIMENTATION AVANT LE DEPANNAGE.
ACH580-3PxR
R3 5-15 HP
Type 1
Px1-31
37
for all other information.
Drive With Input Disconnect
ACH580
Drive
WARNING
RISK OF FIRE OR ELECTRIC SHOCK-
The opening of the branch-circuit protective device may
be and indication that a fault current has been
interrupted. All current-carrying parts and other
components protected by this device should be
examined and replaced if damaged. If burnout of a
current element of an overload relay occurs, the
complete overload relay must be replaced.
!
WARNING
Wait at least 5 minutes after disconnecting
supply before continuing to work.
Consult the Installation & Start-Up Manual
before working on the frequency converter.
!
ATTENTION!
Attendre au moins 5 min apres sectionnement
de l'alimntation pour travailler sur l'appareil.
Consulter le Manuel d'installation et de mise
end route avant d'intervenir sur le convertisseur
de frequence.
CAUTION
VOLTAGE MAY BE PRESENT FROM MORE
THAN ONE SOURCE AND SHOULD BE
DISCONNECTED FOR SERVICING.
ATTENTION
PEUT ETRE SOUS TENSION DE PLUS D'UNE
SOURCE D'ALIMENT ELECTRIQUE. COUPER TOUTES LES
SOURCES D'ALIMENTATION AVANT LE DEPANNAGE.
ACH580-3PxR
R6 20-60 HP
Type 1
Px1-32
Motor
3