Mitsubishi Electric 800 Series Instruction Manual page 370

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Setting
Monitor item
value
53
PID measured value
54
PID deviation
*1
"*" shows a monitor item with a high-speed sampling cycle.
*2
The monitor items with a circle (○) represents that its monitor value can be indicated with minus sign.
*3
Indicates a criterion at 100% when the analog trigger is set.
*4
Refer to the full-scale value of terminal FM or AM (on
*5
Rated motor frequency × 120 / number of motor poles
 Digital source (monitor item) selection
• Select the digital sources (input/output signals) to be set to Pr.1038 to Pr.1045 from the following table. When a value
other than the ones in the following table is set, "0" (OFF) is applied for indication.
Setting
Signal
Pr.
value
name
0
*1
1
178
STF
2
STR
179
*1
5
180
RL
*1
6
181
RM
*1
7
182
RH
*1
9
183
MRS
*1
11
184
RES
21
X0
22
X1
23
X2
24
X3
25
X4
26
X5
27
X6
28
X7
29
X8
30
X9
31
X10
32
X11
33
X12
34
X13
35
X14
36
X15
37
DY
*1
Fixed to OFF state in the Ethernet model.
Trigger
Minus (-)
*1
level
*2
display
criterion
*4
*4
page
Remarks
Input status of an external
input terminal
For the details of the signals,
refer to
page
283.
Input status of a terminal of
the FR-A8AX (option)
Setting
Monitor item
value
*3
237
*Excitation current command
238
*Torque current command
237).
Setting
Signal
value
name
*1
101
190
RUN
*1
105
191
FU
106
A,B,C
192
121
DO0
313
122
DO1
314
123
DO2
315
124
DO3
316
125
DO4
317
126
DO5
318
127
DO6
319
128
RA1
320
129
RA2
321
130
RA3
322
Forward
152
running
Reverse
153
running
156
NET Y1
193
159
NET Y2
194
160
NET Y3
195
161
NET Y4
196
202
NET STF
203
NET STR
204
NET RL
180
205
NET RM
181
206
NET RH
182
208
NET MRS 183
NET
209
JOG2
210
NET X1
185
211
NET X2
186
212
NET RES
184
213
NET X3
187
214
NET X4
188
215
NET X5
189
Trigger
Minus (-)
*1
level
*2
display
criterion
100%
100%
Pr.
Remarks
For the details of the signals,
refer to
page
250.
Output status of a terminal of
the FR-A8AY (option)
Output status of a terminal of
the FR-A8AR (option)
Output status of the signal
(via communication)
For the details of the signals,
refer to
page
250.
Input status of the signal (via
communication)
For the details of the signals,
refer to
page
283.
14. (A) Application Parameters
14.12 Trace function
11
*3
12
13
14
15
16
17
18
19
20
369