 Input signal list
• Refer to the following table and set the parameters.
Signal
Setting
name
0
RL
1
RM
2
RH
3
RT
4
AU
5
JOG
7
OH
8
REX
10
X10
12
X12
14
X14
15
BRI
16
X16
18
X18
24
MRS
STP
25
(STOP)
26
MC
27
TL
30
JOG2
37
X37
46
TRG
47
TRC
50
SQ
51
X51
60
STF
61
STR
62
RES
65
X65
66
X66
67
X67
72
X72
92
X92
9999
-
*1
When Pr.59 Remote function selection ≠ "0", functions of the RL, RM, and RH signals are changed as shown in the table.
*2
When Pr.270 Stop-on-contact control selection = "1", functions of the RL and RT signals are changed as shown in the table.
*3
The OH signal is activated when the relay contact is open.
284
12. (T) Multi-Function Input Terminal Parameters
12.6 Input terminal function selection
Function
Pr.59 = "0" (initial value)
*1
Pr.59 ≠ "0"
*2
Pr.270 = "1"
Pr.59 = "0" (initial value)
*1
Pr.59 ≠ "0"
Pr.59 = "0" (initial value)
*1
Pr.59 ≠ "0"
Second function selection
*2
Pr.270 = "1, 11"
Terminal 4 input selection
Jog operation selection (Available for the standard model only)
*3
External thermal relay input
15-speed selection (Combination with multi-speeds of RL, RM, and
RH)
Inverter run enable (FR-XC/FR-HC2/FR-CV connection)
PU operation external interlock
PID control valid
Brake opening completion
PU/External operation switchover (External operation with X16-ON) Pr.79, Pr.340
V/F switchover (V/F control with X18-ON)
Output stop
Start self-holding selection
Control mode switchover
Torque limit selection
Traverse function selection
Trace trigger input
Trace sampling start/end
Sequence start
Fault clear
Forward rotation command (assignable to the STF terminal
(Pr.178) only)
Reverse rotation command (assignable to the STR terminal
(Pr.179) only)
Inverter reset
PU/NET operation switchover (PU operation with X65-ON)
External/NET operation switchover (NET operation with X66-ON)
Command source switchover (command by Pr.338 or Pr.339
enabled with X67-ON)
PID P control switchover
Emergency stop
No function
Low-speed operation command
Remote setting (setting clear)
Stop-on-contact selection 0
Middle-speed operation
command
Remote setting (deceleration)
High-speed operation command
Remote setting (acceleration)
Stop-on-contact selection 1
Related parameter
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.270, Pr.275, Pr.276
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.44 to Pr.48, Pr.51, Pr.450
to Pr.463, Pr.569, Pr.832,
Pr.836, etc.
Pr.270, Pr.275, Pr.276
Pr.267
Pr.15, Pr.16
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.17, Pr.30, Pr.70
Pr.79
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.278 to Pr.283
Pr.80, Pr.81, Pr.800
Pr.17
Pr.250
Pr.800
Pr.815
Pr.15, Pr.16
Pr.592 to Pr.597
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.414
Pr.414
Pr.250
Pr.250
Pr.75
Pr.79, Pr.340
Pr.79, Pr.340
Pr.338, Pr.339
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.1103
Refer to
page
195
165
324
195
165
195
165
289
324
266
194
198
195
386
174
329
320
174
86
287
291
86
100
194
327
366
366
362
362
291
291
128
174
174
185
329
158