4.1.5
Address space
Address space of the technology module
Table 4- 3
Size per technology channel
Size in one-channel operation
Size in two-channel operation
4.1.6
Control and feedback interface
Note
A library of PLC data types (LPD) for STEP 7 (TIA Portal) and SIMATIC S7-1200 / S7-1500
is available for download on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/109482396).
4.1.6.1
Assignment of the control interface
The user program uses the control interface to influence the behavior of the technology
module.
Control interface per channel
The following table shows the control interface assignment:
Byte
offset
Bit 7
relative
to start
address
Channel
0/1
↓ ↓
0
12
...
...
3
15
4
16
...
...
7
19
8
20
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 05/2019, A5E35061186-AB
Size of input and output addresses
Bit 6
Bit 5
Reserved
Inputs
8 bytes
8 bytes
16 bytes
Bit 4
Bit 3
OUTPUT_VALUE
UDINT: Pulse duration
SLOT
UDINT: Load value
MODE_
SLOT
Configuring/address space
4.1 Pulse output (single pulse) mode
Outputs
12 bytes
12 bytes
24 bytes
Bit 2
Bit 1
LD_SLOT
Bit 0
29