Mitsubishi Electric AE-200A Instruction Book page 11

Air conditioning control system
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

3-1-2. Group icons
Each group icon indicates the operation condition of the group. Touch the icon, and then touch [Operate] to bring up
the operation settings screen.
[1] Air conditioning unit group
ON
Schedule set
*3
Occupied/Vacant
*5 *6 *7
(blue)
(gray)
Note: Besides the 4-way airflow unit icons, 2-way airflow or ceiling-suspended unit icons are also available. Icons can be selected on
the [Groups] screen.
*1 If the LOSSNAY unit is interlocked with the operation of Mr. Slim units, "Interlocked LOSSNAY ON" icon will appear, even when the LOSSNAY
unit is operated individually.
(Applicable M-NET adapter model: PAC-SF48/50/60/70/80/81MA-E)
*2 If a LOSSNAY unit is interlocked with the operation of indoor units in multiple groups, the LOSSNAY unit may be in operation, even when the
"Interlocked LOSSNAY OFF" icon is displayed.
*3 If any schedule setting is applied to a DIDO controller whose prohibition setting is enabled ([Allow operations] is set to [No operations] on the
[Groups] screen), the "Schedule set" icon will appear, but the scheduled operations will not be performed.
*4 The "Energy-saving ON" icon will appear while the Peak Cut control is performed on the group or on the outdoor unit that is connected to the
group.
*5 The Occupancy/Vacancy status icon will appear only when [
section on the [Unit Info.] screen.
*6 The Occupancy/Vacancy status icon will not appear if the remote controller in the group does not have an occupancy sensor.
*7 The Occupancy/Vacancy status icon takes priority over the "Interlocked LOSSNAY ON" or "Interlocked LOSSNAY OFF" icon.
*8 The Brightness/Darkness status icon will appear only when [
[Brightness Sensor] section on the [Unit Info.] screen.
*9 The Brightness/Darkness status icon will not appear if the remote controller in the group does not have a brightness sensor.
*10 The "Setback ON" icon takes priority over the Brightness/Darkness status icon.
*11 The "Starting up" icon will stay when the unit cannot be recognized after startup. Check for proper connection of the air conditioning unit and
proper group settings.
*12 The Hold function can be used on the AE-200A/AE-50A, but not on the AE-200E/AE-50E.
[2] LOSSNAY unit (ventilator) group
ON
Energy-saving ON
*1
*1 The "Energy-saving ON" icon will appear while the Peak Cut control is performed on the LOSSNAY unit group.
WT07190X01
OFF
Schedule disabled
Energy-saving ON
Bright/Dark
Room temperature
*8 *9 *10
(yellow)
(gray)
OFF
HOLD ON
Interlocked
Error
LOSSNAY ON
*4
Setback ON
Room humidity
display
] (blue), [
] (gray), or [
] (yellow), [
] (gray), or [
Error
Schedule set
11
Interlocked
*1 *7
LOSSNAY OFF
*10
Starting up
HOLD ON
display
] (blue/gray) is selected in the [Occupancy]
] (yellow/gray) is selected in the
Schedule disabled
*2 *7
*11
*12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae-50aAe-50eAe-200eAe-50

Table of Contents