For rotary valves, or for actuators with rotations greater than 60°, the magnet assembly must
be aligned as shown in Figure 38.
Increasing Signal = CCW Rotation
Figure 38 Magnet Orientation for 90° Valve Rotation with De-energized Actuator
NOTE
For reciprocating valves the adjustable link turnbuckle must be parallel to the valve stem. To
ensure linearity in positioning verify that the hole in the lever aligns with the indicating hole in
the bracket when the valve is in the closed position. Check that the bracket is mounted on the
correct holes. (See Figure 39 for details).
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Magnet
Axis
with
Valve Closed
For a reciprocating valve, it is not necessary to remove the
positioner to visually inspect the magnet setting and linkage of a
reciprocating valve.
Figure 39 Reciprocating Valve Mounting Bracket
°