GE UR Series Instruction Manual page 371

Line differential relay
Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 38)
ADDR
REGISTER NAME
2486
Terminal 1 IA Magnitude
2488
Terminal 1 IB Magnitude
248A
Terminal 1 IC Magnitude
248C
Terminal 2 IA Magnitude
248E
Terminal 2 IB Magnitude
2490
Terminal 2 IC Magnitude
2492
Differential Current IA Magnitude
2494
Differential Current IB Magnitude
2496
Differential Current IC Magnitude
2498
Local IA Angle
2499
Local IB Angle
249A
Local IC Angle
249B
Terminal 1 IA Angle
249C
Terminal 1 IB Angle
249D
Terminal 1 IC Angle
249E
Terminal 2 IA Angle
249F
Terminal 2 IB Angle
24A0
Terminal 2 IC Angle
24A1
Differential Current IA Angle
24A2
Differential Current IB Angle
24A3
Differential Current IC Angle
24A4
Op Square Current IA
24A6
Op Square Current IB
24A8
Op Square Current IC
24AA
Restraint Square Current IA
24AC
Restraint Square Current IB
24AE
Restraint Square Current IC
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital I/O states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (64 items)
Expanded Remote I/O Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (32 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
Fault Report Indexing (Read Only Non-Volatile)
3020
Number Of Fault Reports
Fault Reports (Read Only Non-Volatile) (10 modules)
3030
Fault Time
3032
...Repeated for module number 2
3034
...Repeated for module number 3
3036
...Repeated for module number 4
3038
...Repeated for module number 5
303A
...Repeated for module number 6
303C
...Repeated for module number 7
GE Power Management
RANGE
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
-359.9 to 0
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 4294967295
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
º
0.1
F002
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
0.001
F060
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F001
---
1
F050
DEFAULT
0
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
0 (Off)
0
0
0
0
0 (No)
0 (No)
0
0
B-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

L90

Table of Contents