7
7.6
1SXU 132 021 M0201
Chapter 7
Settings and configuration
7:1.1 Overview of all accessible settings (different menus) cont.
Description
Function of programmable input In1
Function of programmable output relay K4
Function of programmable output relay K5
Function of programmable output relay K6
Function of programmable software relay V7
Overload event of relay K4
Fault event of relay K4
Shunt fault of relay K4
High current event of relay K4
Thyristor overload event of relay K4
Locked rotor event of relay K4
Underload event of relay K4
Phase imbalance event of relay K4
PTC event of relay K4
Phase reversal event of relay K4
Warning motor overload event of relay K4
Warning thyristor overload event of relay K4
Warning high current event of relay K4
Warning low current event of relay K4
Overload event of relay K5
Fault event of relay K5
Shunt fault of relay K5
High current event of relay K5
Thyristor overload event of relay K5
Locked rotor event of relay K5
Underload event of relay K5
Phase imbalance event of relay K5
PTC event of relay K5
Phase reversal event of relay K5
Warning motor overload event of relay K5
Warning thyristor overload event of relay K5
Warning high current event of relay K5
Warning low current event of relay K5
Overload event of relay K6
Fault event of relay K6
Shunt fault of relay K6
High current event of relay K6
Thyristor overload event of relay K6
Locked rotor event of relay K6
Underload event of relay K6
Phase imbalance event of relay K6
PTC event of relay K6
Phase reversal event of relay K6
Warning motor overload event of relay K6
Warning thyristor overload event of relay K6
Warning high current event of relay K6
Warning low current event of relay K6
Overload event of relay V7
Fault event of relay V7
High current event of relay V7
Thyristor overload event of relay V7
Locked rotor event of relay V7
Underload event of relay v7
Phase imbalance event of relay V7
Display
Setting
text
range
None, Reset,
Enable Jog, DOL,
In1
Start 3, FB-Dis
Relay K4
Run, TOR, Event
Relay K5
Run, TOR, Event
Relay K6
Run, TOR, Event
SW Outp V7
Run, TOR, Event
K4 Overload
Yes, No
K4 Fault
Yes, No
K4 Shunt Fault
Yes, No
K4 High I
Yes, No
K4 SCR OL
Yes, No
K4 Lock Rot
Yes, No
K4 Underload
Yes, No
K4 Phase Imb
Yes, No
K4 PTC
Yes, No
K4 Phase Rev
Yes, No
K4 Warn OL
Yes, No
K4 Wa SCR OL
Yes, No
K4 Wa I=High
Yes, No
K4 Wa I=Low
Yes, No
K5 Overload
Yes, No
K5 Fault
Yes, No
K5 Shunt Fault
Yes, No
K5 High I
Yes, No
K5 SCR OL
Yes, No
K5 Lock Rot
Yes, No
K5 Underload
Yes, No
K5 Phase Imb
Yes, No
K5 PTC
Yes, No
K5 Phase Rev
Yes, No
K5 Warn OL
Yes, No
K5 Wa SCR OL
Yes, No
K5 Wa I=High
Yes, No
K5 Wa I=Low
Yes, No
K6 Overload
Yes, No
K6 Fault
Yes, No
K6 Shunt Fault
Yes, No
K6 High I
Yes, No
K6 SCR OL
Yes, No
K6 Lock Rot
Yes, No
K6 Underload
Yes, No
K6 Phase Imb
Yes, No
K6 PTC
Yes, No
K6 Phase Rev
Yes, No
K6 Warn OL
Yes, No
K6 Wa SCR OL
Yes, No
K6 Wa I=High
Yes, No
K6 Wa I=Low
Yes, No
V7 Overload
Yes, No
V7 Fault
Yes, No
V7 High I
Yes, No
V7 SCR OL
Yes, No
V7 Lock Rot
Yes, No
V7 Underload
Yes, No
V7 Phase Imb
Yes, No
Low Voltage Products & Systems
ABB nc. • 888-385-1221 • www.abb-control.com
Default
Actual
value
setting
Reset
Run
TOR
Event
Event
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
No
No
No
No