GE N60 Instruction Manual page 334

Network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

FLEXLOGIC
Operand type
FIXED OPERANDS
INPUTS/OUTPUTS:
Contact inputs
INPUTS/OUTPUTS:
Contact outputs,
current
(from detector on
form-A output only)
INPUTS/OUTPUTS:
Contact outputs,
voltage
(from detector on
form-A output only)
INPUTS/OUTPUTS:
Direct analog inputs
5
INPUTS/OUTPUTS:
Direct inputs
INPUTS/OUTPUTS:
RxGOOSE DPS
INPUTS/OUTPUTS:
RxGOOSE Booleans
INPUTS/OUTPUTS:
Virtual inputs
INPUTS/OUTPUTS:
Virtual outputs
5-174
Operand syntax
UNDERFREQ 2 to 6
Off
On
Cont Ip 1 On
Cont Ip 2 On
Cont Ip 1 Off
Cont Ip 2 Off
Cont Ip 96 On
Cont Ip 96 Off
Cont Op 1
IOn
Cont Op 2
IOn
Cont Op 64
IOn
Cont Op 1 VOn
Cont Op 2
VOn
Cont Op 64
VOn
Cont Op 1
VOff
Cont Op 2
VOff
Cont Op 64
VOff
DIR ANA 1 DEADBAND
DIR ANA 1 FORCE
DIR ANA 1 INTEGRITY
DIR ANA 2 to 32
DIRECT INPUT 1 On
DIRECT INPUT 64 On
RxG DPS 1 BAD
RxG DPS 1 INTERM
RxG DPS 1 OFF
RxG DPS 1 ON
RxG DPS 2 to 5
RxG Bool 1 On
RxG Bool 2 On
RxG Bool 3 On
RxG Bool 256 On
Virt Ip 1 On
Virt Ip 2 On
Virt Ip 3 On
Virt Ip 64 On
Virt Op 1
On
Virt Op 2
On
Virt Op 3
On
Virt Op 96
On
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
Operand description
Same set of operands as shown for UNDERFREQ 1
Logic = 0. Does nothing and can be used as a delimiter in an equation list;
used as 'Disable' by other features.
Logic = 1. Can be used as a test setting.
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
(does not appear unless ordered)
A deadband has triggered direct analog input 1
A user force operand has triggered direct analog input 1
An integrity timeout has triggered direct analog input 1
Same set of operands as per DIRECT ANA 1
Flag is set, logic=1
Flag is set, logic=1
Asserted while the RxGOOSE double-point status input is in the bad state
Asserted while the RxGOOSE double-point status input is in the intermediate
state
Asserted while the RxGOOSE double-point status input is off
Asserted while the RxGOOSE double-point status input is on
Same set of operands as per RxG DPS 1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
CHAPTER 5: SETTINGS