Invalid Password Entry - GE N60 Instruction Manual

Network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

FRONT PANEL INTERFACE
Clearing the event records
Clearing the oscillography records
Changing the date and time
Clearing energy records
Clearing the data logger
Clearing the user-programmable pushbutton states
To enter the initial setting or command password:
1.
Press the
MENU
display.
2.
Press the
MESSAGE
3.
Press the
MESSAGE
4.
Press the
MESSAGE
appears on the display.
 SECURITY

4
5.
After the
CHANGE...PASSWORD
selection to "Yes."
6.
Press the
ENTER
7.
Type in a password and press the
8.
When
VERIFY NEW PASSWORD
CHANGE SETTING
PASSWORD: No
CHANGE SETTING
PASSWORD: Yes
9.
When the
NEW PASSWORD HAS BEEN STORED

4.2.11 Invalid password entry

By default, when an incorrect Command or Setting password has been entered via the faceplate interface three times
within five minutes, the
command level access via the faceplate interface for five minutes.
By default, when an incorrect Command or Setting password has been entered via any external communications interface
three times within five minutes, the
settings or command access via the any external communications interface for five minutes. The
FlexLogic operand is set to "Off" after five minutes for a Command password or 30 minutes for a Settings password.
These default settings can be changed in EnerVista under Settings > Product Setup > Security.
4-30
key until the
header flashes momentarily and the
SETTINGS
right arrow until the
ACCESS LEVEL
down arrow until the
CHANGE LOCAL PASSWORDS
right arrow until the
CHANGE SETTING PASSWORD
ACCESS LEVEL:
Restricted
 CHANGE LOCAL
 PASSWORDS
message appears on the display, press the
key and the display prompts you to
key.
ENTER
displays, re-type the password and press
ENTER NEW
PASSWORD: ##########
message appears, your new Setting (or Command) password is active.
FlexLogic operand is set to "On" and the N60 does not allow settings or
LOCAL ACCESS DENIED
REMOTE ACCESS DENIED
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
PRODUCT SETUP
message appears on the display.
message appears on the display.
or
CHANGE COMMAND PASSWORD
CHANGE COMMAND
PASSWORD: No
CHANGE SETTING
PASSWORD: No
up or down arrow to change the
VALUE
.
ENTER NEW PASSWORD
.
ENTER
FlexLogic operand is set to
"
CHAPTER 4: INTERFACES
message appears on the
message
VERIFY NEW
PASSWORD: ##########
NEW PASSWORD
HAS BEEN STORED
On
and the N60 does not allow
"
REMOTE ACCESS DENIED

Advertisement

Table of Contents
loading

Table of Contents