Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
140507-012
RTIF2-
x
140507-014
RTIF2-
x
140507-016
RTIF2-
x
140507-021
RTIF2-
x
140507-022
Description
In a system with several SPARC M10-4S,
if a crossbar box or the XSCF unit of a
crossbar box is replaced after powering
off all chassis and then the input power is
turned on, the following error log may be
registered.
Indispensable parts are not installed
(OPNL).
Indispensable parts are not installed
(FAN).
Indispensable parts are not installed
(PSU).
When replacefru(8), addfru(8) or,
rebootxscf(8) command is executed, the
"XSCF hang-up is detected" error
message may be detected at the slave
XSCF.
After configuring the XSCF network with
the setnetwork(8) command and
applying the configuration by the
applynetwork(8) command, if the
shownetwork(8) command is executed
without executing the rebootxscf(8)
command, the displayed IP address may
not match the IP address that is being
used on the present system.
In the middle of performing diagnosis by
the "-p" and "-b" options of the
diagxbu(8) command, if a failure occurs
in the physical partition specified by the
"-p" option, the diagxbu(8) command
may terminate abnormally and powering
off the SPARC M10 chassis, specified by
the "-b" option may fail.
When the crossbar cable of the crossbar
unit (XBU) in SPARC M10-4S is in bad
electrical contact, the crossbar cable
components are depicted with a number
Workaround
original microSD card.
6. Turn on the input power of the system
(AC ON).
When replacing a crossbar box, do so
after turning off the input power (AC
OFF) of the target crossbar box only.
When replacing the XSCF unit of a
crossbar box, execute the replacefru(8)
command to do so.
Refer to Fujitsu M10-4/Fujitsu M10-4S/
SPARC M10-4/SPARC M10-4S Service
Manual for replacing the crossbar box or
the XSCF unit in the crossbar box.
[How to Restore]
Turn off/on the input power (AC
OFF/ON) of the replaced crossbar box.
There is no effective workaround.
Ignore this error log as the command in
question is terminated properly and thus
it has no effect on the system.
After executing the applynetwork(8)
command to apply network configurations
of the XSCF, execute the rebootxscf(8)
command to reset the XSCF.
There is no effective workaround.
[How to Restore]
Perform the following procedure:
1. Turn off the input power (AC OFF) of
SPARC M10 chassis using the "-b"
option of the diagxbu(8) command.
2. Select the SPARC M10 chassis by the
"-b" option of the replacefru(8)
command.
3. When the message for the replacement
of SPARC M10 chassis is output in the
maintenance menu, turn on the input
power (AC ON) of the SPARC M10
chassis without replacing it.
There is no effective workaround.
[How to Restore]
Perform the following procedures:
1. Power off the physical partition
Chapter 3 Information on Software
69