Table 7-4     Problems resolved in version 1150 of the PCI expansion unit firmware (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131224-002
Problems resolved in version 1130 of the PCI
expansion unit firmware
The following table lists the problems resolved in version 1130 of the PCI expansion
unit firmware.
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
196
Description
When the PCI Expansion Unit and
the chassis of SPARC M10 system
are connected by optical cables in a
low-temperature environment,
optical cable error logs may be
registered.
This symptom can be confirmed by
the "showlogs error -v" command.
If the result of the "showlogs error
-v" command is "Msg: LINKCBL
failed", and the 3rd byte of the 4th
line of the "Diagnostic Code" is
either "10", "50" or "60", it
corresponds to this symptom.
[Example of the error message]
In case the 3rd byte of the 4th line
of the "Diagnostic Code" is "10":
XSCF> showlogs error -v
Date: Dec 17 15:50:11 JST 2013
Code: 10000400-
009eff0000ff0000ff-
110000440000000000000000
Status: Information Occurred: Dec
17 15:50:06.930 JST 2013
FRU: /BB#0/PCI#3/LINK/
LINKCBL#1
Msg: LINKCBL failed
Diagnostic Code:
00030001 00000000 0000
00030000 00000000 0000
00030000 00000000 0000
00001000 00000000 00000000
00000000
00000000 00000000 0000
Workaround
Ignore this error message as it has no effect on
the system.