Table 3-9     Problems resolved in XCP 2230 (continue d)
SPARC M10-
RTINo.
1
4
4S
RTIF2-
x
x
x
140623-003
RTIF2-
x
x
x
140731-001
RTIF2-
x
140805-001
Description
Suppose that the XSCF STANDBY LED
on the operation panel blinks immediately
after turning on the input power (AC
ON). If the power switch on the
operation panel is pressed, powering
on/off the physical partition (PPAR)
becomes disabled.
The power to the PPAR is turned on/off
when:
- The power switch on the operation
panel is manipulated.
- The poweron(8) or poweroff(8)
command is executed.
- PPAR power on/off operation is
performed on XSCF Web.
- Power supply interlocking by RCIL
takes place.
- The auto power control system (APCS)
issues a power on/off instruction.
An Event Log ("Host stopped") is not
displayed by a showlogs(8) event and
showmonitorlog(8) when the primary
domain is shutdown.
If the system board is deleted by the
dynamic reconfiguration of physical
partitions, a process on the logical
domains may produce a core dump by
SIGILL (Illegal Instruction).
Workaround
To operate the power switch on the
operation panel immediately after
turning on the input power, wait at least
30 seconds after the STANDBY LED
switches from blinking to being
constantly on.
There is no effective workaround.
There is no effective workaround.