Problems Resolved In Xcp 2090 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-14     Problems resolved in XCP 2091
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140117-001

Problems resolved in XCP 2090

The following table lists the problems resolved in XCP 2090.
Table 3-15     Problems resolved in XCP 2090
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
130219-003
RTIF2-
x
130219-007
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
116
Description
When the setsnmp(8), setsnmpusm(8),
setsnmpvacm(8) commands or [XSCF] -
[Settings] - [Service] - [SNMP], [XSCF] -
[Settings] - [Service] - [SNMP Security]
on XSCF Web is executed, the "exclusive
control file open error" error message is
output and all setups regarding SNMP
fail. This problem occurs only on XCP
2090.
Description
The following error log is registered if
you remove a XSCF BB control cable
when removing a SPARC M10-4S with
the initbb(8) command or replace a
SPARC M10-4S or an XSCF unit with the
replacefru(8) command.
Msg: Board control error (MBC link error)
Msg: BB control cable detected unexpected
Msg: XSCF hang-up is detected
When you turn on the input power to a
crossbar box or SPARC M10-4S after
disconnecting it in a system having a
building block configuration, "Board
control error (MBC link error)" may be
registered in the error log. In addition, an
non-existing crossbar box or SPARC
M10-4S may be displayed as a faulty unit.
Workaround
Update firmware either to XCP 2080 or
older, or to 2091 or later.
Workaround
There is no effective workaround.
Ignore the error log.
This error log is registered when you
disconnect the input power supply.
Ignore this error log.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents