supported.
Alive monitoring between the XSCF and a Hypervisor is not supported. Alive
monitoring between the XSCF and a Hypervisor cannot be enabled/disabled even
by using the setpparmode(8) command.
[SPARC M10-4S]
Suppose that the XSCF was switched while connecting to the control domain
console in the SPARC M10-4S that is composed of more than two chassis. In that
case, connection to the control domain console may not be established until all the
SPARC M10-4S chassis have been restarted if an attempt has been made to
reconnect the control domain console to the switched master XSCF.
If all XSCFs have not been restarted due to an error in the XSCF, establish a
connection to the control domain console again. Replace a failed XSCF or CPU
memory unit lower (CMUL) if a connection cannot be established to the control
domain console.
[SPARC M10-4S]
The poweroff(8) and reset(8) commands may not be executed normally if all XSCF
have not been restarted due to an error in a XSCF in the SPARC M10-4S that is
composed of more than two chassis.
To disconnect the power of a physical partition (PPAR), login to the control
domain of the PPAR and execute the shutdown(1M) command on Oracle Solaris.
Then, disconnect the power of the PPAR using the poweroff -f command on the
XSCF firmware. The reset(8) command cannot be used in this state.
The -c wait option, which is used to set the wait time before the system is started
for the setpowerupdelay(8) command, is not supported at present.
Replacement of a crossbar box using the replacefru(8) command is not supported
at present. For how to replace a crossbar box, see
crossbar
box" in "Chapter 6 Information on SPARC M10-4S Hardware."
Addition of a crossbar box using the addfru(8) command is not supported at
present. For how to add a crossbar box, see
2" in "Chapter 6 Information on SPARC M10-4S Hardware."
[SPARC M10-4S]
If you power on all physical partitions (PPAR) in a system that has more than one
PPARs with the poweron(8) command, the startup time taken when specifying
power-on of PPAR is longer than the time taken for batch power-on by specifying
-a.
[SPARC M10-4/M10-4S]
As for the ioreconfigure that can be specified by -m function of the setpparmode
(8) command, leave it as the default, false, and disable the I/O bus reconfiguration
function. If you enable the I/O bus reconfiguration function by specifying true to
the ioreconfigure, it may be necessary to reinstall Oracle Solaris.
[SPARC M10-4S]
If showhardconf -M is executed, it may not be possible to display one screen at a
time if both of the conditions below are met. Do not execute showhardconf -M.
- System configured with 2BB or more
- One or more SPARC M10-4S units are subject to an XSCF reset by the
"Restrictions on replacing
"Restrictions on adding expansion rack
Chapter 2 XCP 2240-Related Information
31