Advertisement

Table 7-3     Problems resolved in version 1170 of the PCI expansion unit firmware (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140902-001
RTIF2-
x
x
x
140902-002
Description
If input power for the PCI
expansion unit is disconnected (AC
OFF) or power failure occurs, a
PSU "Information" level error log is
supposed to be registered.
However, a failure level error log
"Alarm" is incorrectly registered. At
this point, CHECK LED on the
front of the PCI expansion unit
lights up, "Faulted" is displayed on
the PSU status, and the error
message "AC Fail" is displayed.
You can check the error message of
this phenomenon by executing the
showlogs error command, and
check the status by executing the
showhardconf command.
[Error message example]
XSCF> showlogs error
Date: Jul 10 16:25:02 JST 2014
Code: 80000400-
00d4000000ff0000ff-
1100002a0000000000000000
Status: Alarm Occurred: Jul 10
16:24:57.269 JST 2014
FRU: /BB#0/PCI#8/PCIBOX#2003/
PSU#1
Msg: AC FAIL
[PSU status example]
XSCF> showhardconf
--- Omitted ---
PCIBOX#2003; Status:Normal;
Ver:1150h; Serial:2121152003;
--- Omitted ---
* PSU#1; Status:Faulted; Serial:
FEJD1201000170;
Link card fault may be incorrectly
registered if logs related to one PCI
expansion unit are registered more
than once in a short time (5 to 10
minutes) when one or more
physical partitions (PPAR) are
operating in the configuration with
PCI expansion units connected.
For details, see
"Confirmation
method of
RTIF2-140902-002".
Workaround
Update the PCI expansion unit firmware to
1170 or later, and the XCP firmware to XCP
2220 or later. There is no impact on system
operation from this phenomenon.
Ignore this error message because there is no
impact on system operation.