Connecting Multiple Inverters To The Smartlogger - Huawei SmartLogger2000 User Manual

Hide thumbs Also See for SmartLogger2000:
Table of Contents

Advertisement

SmartLogger2000
User Manual
Verify that the N485A_IN port on the SUN8000 is connected to Surge port 1 or 7 on the
RS485 signal SPD, and that the N485B_IN port on the SUN8000 is connected to Surge port 5
or 11 on the RS485 signal SPD.
Step 5 Use a flat-head screwdriver to tighten the screws on the Surge ports, as shown by (2) in
Figure 4-23.
Step 6 Set Baud Rate for the SUN8000 to the same Baud Rate configured for the SmartLogger.
----End
Follow-up Procedure
Take operations in reversed order to disconnect the SmartLogger from the SUN8000.

4.4.3 Connecting Multiple Inverters to the SmartLogger

The SmartLogger can connect to multiple inverters through a daisy chain or an AC power
cable.
Daisy Chain Connection
In the daisy chain connection mode, the RS485OUT of one inverter is connected to the
RS485IN port of the next inverter, and the first inverter is connected to the SmartLogger as
described in Connecting the SUN2000 Using an RS485 Communications Cable or 4.4.2
Connecting the SUN8000 in 4.4.1 Connecting the SUN2000. Figure 4-24 shows the
connection.
(2016-06-20)
For details about the communications parameters settings for the SmartLogger, see
Setting RS485 Parameters or SUN2000 APP User Manual.
For details about the communications parameters settings for the SUN8000, see
SUN8000-500KTL User Manual.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Connecting Cables
54

Advertisement

Table of Contents
loading

Table of Contents