Context
The Ethernet cable has the following functions:
l
l
Using the CPRI_E1 port on the pRRU3901 has the same Ethernet cable connection to the
RHUB as using the CPRI_E0 port. The following section describes the connection using the
CPRI_E0 port.
Procedure
Step 1 Make the Ethernet cables.
1.
2.
3.
4.
Step 2 Connect the RJ45 connector at the other end of the Ethernet cable to any port ranging from
CPRI_E0 to CPRI_E7 on the RHUB panel based on the engineering design.
Step 3 Optional: Connect the RJ45 connector at the other end of the Ethernet cable to the output
port of the Extender. Then, connect the RJ45 connector at one end of another Ethernet cable
to the input port of the Extender.
If the Extender is used, the Ethernet cable is divided into two parts, one between the RHUB
and the Extender and the other between the Extender and the pRRU.
Step 4 Remove the dustproof cap of the CPRI_E0 port on the pRRU.
Step 5 Connect the RJ45 connector at one end of the Ethernet cable to the CPRI_E0 port on the
pRRU panel, as shown in
Issue 06 (2015-10-30)
Provides power supply for the pRRU when connected to the CPRI_E0 port on the
pRRU.
Transmits CPRI signals between an RHUB and a pRRU.
Assemble an RJ45 connector and an Ethernet cable by following instructions in
Assembling the Unshielded RJ45 Connector and the Ethernet Cable of Installation
Reference.
NOTE
Follow pin assignment instructions described in section Ethernet Cable in DBS3900 LampSite
Hardware Description to assemble the unshielded RJ45 connector and the Ethernet cable. Otherwise,
the transmission signal quality deteriorates and CPRI links may be disconnected.
Check whether the made RJ45 connector is qualified by following instructions in
Checking the Appearance of Metal Contact Strips.
To complete the assembly of the other end, repeat
Check whether the touch points on the connectors at both ends are normally conducted
and well contacted and whether the connections are correct by following instructions in
Testing the Connection of Assembled Cables of Installation Reference.
Figure
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Step 1.1
6-33,
Figure
6-34.
6 Installing an RHUB
and
Step
1.2.
40