Do not perform the operations in the following table during updating the
firmware since the management module operation stops temporarily.
When you perform the operations in the following table during updating
the firmware, the operations may fail. Retry the operations after updating
the firmware.
Manual switching and restoring operation of the N+M cold standby.
(When the operation fails, the re-configuration may be required.)
Logging in to the management module console.
Operating SeverConductor/Blade Server Manager.
Operating SeverConductor/Deployment Manager.
Operating Cm2/Network Node Manager.
Operating HCSM
Using remote console.
Operating LPAR manager.
Updating server blade firmware
Updating LPAR manager firmware
The management module firmware update may fail when you update the
firmware during turning on or off the power of server blade or system
unit. Do not perform the following operation.
Turning on or off the power of server blade or system unit including the operation
directed by the scheduled operation.
The following alert messages may be reported to SeverConductor/Blade
Server Manager during the update.
(The alert messages are reported during the update, but do not affect the
system operation.)
Message type
Alert
Information
2-282
Hitachi Compute Blade 500 Series Management Module Setup Guide
Table 2-152 Firmware code
Prohibited operation
Table 2-153 Prohibited operation
Prohibited operation
Table 2-154 Alert message
0x17A0 LAN port <Management LAN port 0> lacks redundancy.
0x17A0 LAN port <Management LAN port 1> lacks redundancy.
0x17A0 LAN port <Management LAN port> lacks redundancy.
0x17A1 LAN port <Management LAN port 0> redundancy was
restored.