Features - GE MDS SD Series Technical Manual

Secure, long range ip/ethernet & serial wireless transceiver
Hide thumbs Also See for MDS SD Series:
Table of Contents

Advertisement

Advanced Tuning
Dlink Mode (B modems)
port for Dlink. Newer products such as the SD have the ability to support Dlink even
when using B-Modems. Depending on site-specific requirements, this value may need to
be changed to 'bypassed' in order to work with legacy products. It is recommended to
leave this value set to 'auto' unless there is an explicit need to change it.
Modem Transmit Tolerance
19200N and 4800F modems. This value should always be set to normal unless instructed
to change it by GE MDS technical support for specific applications.

Features

Bridge Configuration
— Used to enable or disable Ethernet Bridging on the radio. Default setting
Bridge Mode
is
.
OFF
Basic Bridge Filter Sel
Broadcast/Unicast (All), Unicast and ARP,
Adv Bridge Filter Status
specific Ethernet-enabled device matching one of the Adv Src Addr Filter Values (see
below).
Adv Src Addr Filter 1-4 Val
fields are available. If the Adv Bridge Filter Status is on, and an incoming Ethernet frame
src addr matches any of these values, the radio bridges the frame. Otherwise, it is
dropped by the radio. The entry format must be
Ageout Time (mins)
MAC entry in the Bridge route table. The parameter can be varied from 0 to 5 minutes.
Default for this setting is
50
— Legacy products that only support B-Modems do not have sup-
— Feature to enhance over-the-air data when using 38400N,
— Sets the type of bridge filter to be used. Available selections are:
and
— When on, this filter bridges the Ethernet traffic received from a
— Sets the Advanced SRC Address Filter Values. Four address
— Defines the amount of time (in minutes) a radio holds a specific
minutes.
5
SD Series Technical Manual
.
Unicast Only
xx:xx:xx:xx:xx:xx
.
MDS 05-4846A01, Rev. I

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents