Issue 4.0
84-29 : DT800/DT700 CODEC Information Fixed Mode Setup
Level:
IN
Description
Use Program 84-29 : DT800/DT700 CODEC Information Fixed Mode Setup to set the CODEC data of
the DT800/DT700 when it uses Multicast.
Input Data
Type
Item
No.
01
Audio Capability
02
Number of Audio Frames
03
RTP Filter
To avoid incorrect voice pass connection, this
Program checks the sending side address from
received RTP packet at VoIPDB.
Conditions
When using G.711, PRG 84-29-02 only 10ms, 20ms, 30ms and 40ms are used.
Feature Cross Reference
None
SV9100 Programming Manual
Program 84 : Hardware Setup for VoIP
Item
1 = Type 1 (Multicast)
2 = Type 2 (reserved)
3 = Type 3 (reserved)
4 = Type 4 (reserved)
5 = Type 5 (reserved)
Input Data
Default
1 = G.711 A-law
2 = G.711 -law
3 = G.729
5 = G.722
1~6
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
5 = 50ms
6 = 60ms
0 = Disable
1 = Enable
2
2
1
2-795