Loop Key Data - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Issue 4.0
Level:
IN
Description
Use Program 15-13 : Loop Key Data to set the Loop Key Data for each terminal. Loop Keys can be
Incoming, Outgoing, or both ways. Outgoing Loop Keys use the entry in Item 01. Incoming Loop Keys
use the entry in Item 02. Both Way Loop Keys follow the entries in both Items 01 and 02.
Input Data
Extension Number
Key Number
Item
Item
Number
01
Outgoing Option
02
Incoming Option
Conditions
None
Feature Cross Reference
Loop Key
SV9100 Programming Manual
Program 15 : Extension, Basic Setup
Input Data
0~8 or 0~100
(0 = Assigns the Loop Key for
ARS, 1~100 = Assigns the
Loop Key to the trunk group
specified.)
0~8 or 0~100
(0 = Assigns the Loop Key to all
trunk groups, 1~100 =
Assigns the Loop Key to the
trunk group specified.)

15-13 : Loop Key Data

001 ~ 960
01~48
Default
Programmable Function Key
Number 01~32:
Outgoing Option - 0 (Assigns the
Loop Key for ARS)
Incoming Option - 0 (Assigns the
Loop Key to all trunk groups)
2-223