Center Cutting Unit Raise/Lower Delay
The raise and lower delay time for the center cutting may be
adjusted independently with the InfoCenter. Each setting
may be adjusted from 1 to 10 according to the table below.
The factory default setting is 6 (375 ms) and is optimized for
a 3.8 mph mow speed.
Increment Number
1
2
3
4
5
6
7
8
9
10
Tap-off Delay
The tap-off delay feature allows the cutting units to turn off
without raising, and may be adjusted with the InfoCenter. The
delay setting represents the maximum time for the raise/lower
joystick to remain in the raise position to activate this feature.
The factory default setting is 1 which disables this feature.
Increment Number
1
2
3
4
5
6
7
8
9
10
Setting the Reel Speed
To achieve a consistent, high quality–of–cut and a uniform
after cut appearance, it is important that the reel speed control
be correctly set.
Adjust the reel speed control as follows:
1. Select the height-of-cut at which the cutting units are
set.
2. Choose the desired ground speed best suited for
conditions.
Delay Time (Seconds)
0.100
0.150
0.200
0.250
0.300
0.375
0.475
0.600
0.750
0.925
Delay Time (Seconds)
Off
0.050
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
3. Using the appropriate graph (See
11, or 14 blade cutting units, determine the proper reel
speed setting.
4. To set the reel speed, on the InfoCenter open the Main
Menu and scroll down to Settings.
5. In the Settings menu, scroll down to Reel Speed and
use the ± button to set the reel speed to the desired
number.
Machine Configuration Passcode
There are 5 operating configuration settings that are
adjustable within the setting menu of the InfoCenter: Raise
and lower delay, tap-off delay, reel speed, and backlap speed.
These setting can be protected by a user defined passcode by
opening the Main menu and scrolling down to the Settings
menu. Find Protect Settings and select On.
When protect setting On is selected the user is prompted
to enter a 4 digit passcode. After the passcode is set, the
keyswitch must be turned off and back on to enable and
save this feature. After enabling the protect settings option,
the configuration settings are hidden until the user defined
passcode is entered.
Note: If the user defined passcode is forgotten, a temporary
passcode can be obtained through your authorized Toro
distributor.
Diagnosing the Fault-Log Indicator
The fault-log indicator icon appears on the main screen in the
event of a fault in the machine. When this icon is present
there is a new log entry in the Faults menu that you or your
distributor can use to identify the problem.
For a list of faults, refer to your Authorized Toro Distributor
or the Service Manual.