Color Checks Using The Spectrophotometer Unit (Option) - Canon iPF6400S User Manual

Hide thumbs Also See for iPF6400S:
Table of Contents

Advertisement

iPF6400S
(See "Color Calibration Management Console (Mac OS).")

Color Checks Using the Spectrophotometer Unit (option)

Color Checks Using the Spectrophotometer Unit (option)
Features of Color Checks Using the Spectrophotometer Unit
A color check calculates the difference between the results of color measurement on the pattern built into the print-
er and the calibration target.
Executing a color check prints a pattern, which is then measured automatically by the Spectrophotometer Sensor
on the Spectrophotometer Unit.
The resulting measurement value is then compared with the calibration target stored on the printer, and the corre-
sponding difference is displayed on the Control Panel and Color Calibration Management Console.
When printing the color check pattern, the calibration adjustment values are applied even if Use Adj. Value is set to
Disabled in the Control Panel menu.
Note
(See "Color Calibration Using the Spectrophotometer Unit (option).")
Setting Threshold Values
Threshold values are used in the Color Check process.
Set in the Color Calibration Management Console.
(See "Executing Color Check (Windows).")
(See "Executing Color Check (Mac OS).")
Executing Color Check from the Control Panel on the Printer
Follow the steps below to execute a Color Check from the Control Panel.
Refer to the information on Color Calibration Management Console operations when executing color check from
the computer.
(See "Executing Color Check (Windows).")
(See "Executing Color Check (Mac OS).")
Preparing the Printer
1
First, check whether the paper to be loaded can be used in a Color Check.
The types of paper that can be used in Color Checks are the same as those that can be used in Au-
toAdjst(HiPrc) using the Spectrophotometer Unit.
(See "Displaying the Paper Reference Guide.")
2
Load the paper.
(See "Loading Rolls on the Roll Holder.")
(See "Loading Rolls in the Printer.")
If Adj. Quality has not been executed even once on the paper you are using, execute Adj. Quality in the Con-
trol Panel menu.
Note
(See "Automatic Banding Adjustment.")
3
Select the White/Black Backing Plate color.
(See "Switching the White/Black Backing Plate (Optional) Color.")
For the color of the White/Black Backing Plate, select the color from when color calibration was executed using
the Spectrophotometer Unit.
Note
(See "Color Calibration Using the Spectrophotometer Unit (option).")
4
Select the pattern size.
Set Pattern Size in the Control Panel menu.
(See "Menu Settings.")
To increase the precision of the color check, select the Pattern Size from when color calibration was executed
using the Spectrophotometer Unit.
Note
(See "Color Calibration Using the Spectrophotometer Unit (option).")