Reaction:
Interface signals are set.
Alarm display.
Remedy:
Trigger JOG motion again.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17825
Indexing axis %1 $SA_JOG_POSITION unequal indexing position
Parameters:
%1 = Axis number
Definitions:
The axis is a referenced indexing axis and 'JOG to position' is activated in JOG mode, but SD43320
$SA_JOG_POSITION does not coincide with an indexing position. In JOG mode, referenced indexing axes approach
indexing positions.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify SD43320 $SA_JOG_POSITION or indexing positions.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
17830
[Channel %1: ] JOG in a circle is activated, but the axis %2 required for this is not a
geometry axis.
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The function JOG in circles has been activated, but the axis required for this has not been defined as a geometry axis.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Define axis as geometry axis.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17831
[Channel %1: ] JOG a circle is not possible, reason %2
Parameters:
%1 = Channel number
%2 = Cause
Definitions:
The JOG in circles was activated, but this is not possible because:
1. The current positions of the axes involved lie outside the selected pitch circle.
2. The current positions of the axes involved, with pitch circle selected and tool radius offset active, are too near to the
center of the circle.
3. The current positions of the axes involved, with tool radius offset active, are too near to the limiting circle during
internal machining.
4. The current positions of the axes involved, with tool radius offset active, are too near to the limiting circle during
external machining.
5. The current positions of the axes involved in internal machining are outside the defined circle.
6. The current positions of the axes involved in external machining are inside the defined circle.
10. A rotation is acting on the current plane, that is the current plane is inclined in space. This is not currently sup-
ported.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Define axis as geometry axis.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
289