Block %2 Positioning Axis %3 Cannot Participate In Spline; Block %2 Axis %3 Is Not A Geometry Axis - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
16300
[Channel %1: ] Block %2 denominator polynominal with zero places within parameter
range not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed denominator polynomial (with PL [ ] = ... , i.e. without specification of geometry axis) has a zero place
within the defined parameter range (PL = ...). This means that the quotient of the numerator polynomial and the denom-
inator polynomial is infinite or indeterminate.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify the polynomial block so that there is no zero place within the polynomial length in the denominator polynomial.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16400
[Channel %1: ] Block %2 positioning axis %3 cannot participate in spline
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
An axis assigned to a spline grouping (n) with SPLINEPATH (n, AX1, AX2, ...) has been programmed as positioning
axis with POS or POSA.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Do not assign the positioning axis to the spline grouping.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16410
[Channel %1: ] Block %2 axis %3 is not a geometry axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
A geometry axis has been programmed that cannot be imaged on any machine axis in the current transformation (pos-
sibly there is no transformation active at the moment).
Example:
Without transformation: Polar coordinate system with X, Z, and C axis
With transformation: Cartesian coordinate system with X, Y, and Z, e.g. with TRANSMIT.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Activate transformation type with TRAORI (n) or do not program geometry axes that do not participate in the transfor-
mation grouping.
Program
Clear alarm with NC START or RESET key and continue the program.