Block %2 Illegal Interpolation Type For Contour Definition Active; Block %2 Illegal Language Element In External Language Mode; Block %2 Program Number For Macro Call (G65/G66) Missing; Block %2 Multiple Iso_2/3 Macro Or Cycle Calls In The Block - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
12701
[Channel %1: ] Block %2 illegal interpolation type for contour definition active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In one contour definition block, G01 is not active as interpolation function. In one contour definition block, the linear
interpolation always has to be selected with G01. G00, G02, G03, G33 etc. are not permitted.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Program linear interpolation G01.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12710
[Channel %1: ] Block %2 illegal language element in external language mode
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed language element is not allowed or unknown in external language mode. Only the language ele-
ments from Siemens mode which are used for subprogram calls (except for Lxx) and the language constructs for pro-
gram repetition with REPEAT (UNTIL) are allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Check that the language command is available in Siemens mode. Switch to Siemens mode with G290. Program the
command in the next block and switch back to the external language mode in the following block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12720
[Channel %1: ] Block %2 program number for macro call (G65/G66) missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During macro call with G65/G66 no program number was defined. The program number must be programmed with
address "P".
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12722
[Channel %1: ] Block %2 multiple ISO_2/3 macro or cycle calls in the block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A mixture of cycle and macro calls are programmed in a block, e.g. cycle calls with G81 - G89 together with an M
macro in the block or a G65/G66 macro call together with M macros in the block.
G05, G08, G22, G23, G27, G28, G29, G30, G50.1, G51.1, G72.1, G72.2 functions (ISO mode) also execute subrou-
tine calls. Only one macro or cycle call can appear in an NC block.