Block %2 Iso2 Mode, And Toolcarrier Or Tool Adapter Are Both Active; Block %2 Error %3 On Interpreting The Contents Of $Sc_Cutdirmod - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14186
[Channel %1: ] Block %2 ISO2 mode, and toolcarrier or tool adapter are both active
(identifier %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier
Definitions:
Only relevant in ISO2 mode:
An attempt has been made to activate an ISO2 offset and toolcarrier or tool adapter together.
Identifier 1: ISO2 offset is active (activated in ISO2 mode) and an attempt has been made to activate an additional
toolcarrier in Siemens mode.
Identifier 2: A toolcarrier has been activated in Siemens mode, and a tool offset is now activated in ISO2 mode.
Identifier 3: A tool is active in the adapter in Siemens mode, and a tool offset is now activated in ISO2 mode.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct NC block.
For identifier 1: Select a Siemens offset before activating the toolcarrier.
For identifier 2: Deactivate the toolcarrier before selecting a TLC in ISO2 mode.
For identifier 3: Load a tool (T=0) or activate a tool without an adapter before selecting a TLC in ISO2 mode.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14196
[Channel %1: ] Block %2 error %3 on interpreting the contents of $SC_CUTDIRMOD
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
Definitions:
An error has occured during the interpretation of the strings contained in SD42984 $SC_CUTDIRMOD. This setting
data is always read when a new edge is selected. The error code indicates the cause of the error:
1: The string only consists of blanks or a sign
2: Unknown frame name after $P_
3: No colon after the first valid frame name
4: Insufficient memory space for creating a frame internally
5: Invalid frame index
6: Further characters found after complete string
7: Second frame name is missing after the colon
8: Impermissible frame rotation (surface normals are rotated against each other by 90 degrees or more)
9: Invalid frame chain (the first frame must come before the second frame in the frame chain)
10: Invalid axis name
11: Axis is not a rotary axis
12: Invalid string that cannot be assigned to any of the error types 1 to 11
20: Invalid angle statement (numerical value)
30: Invalid angle of rotation (not an integer multiple of 90 degrees)
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
174
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents