Power over Ethernet (PoE) Commands
78-21075-01 Command Line Interface Reference Guide
Field
Description
Short Counter
Counts the number of short conditions
detected.
Denied Counter
Counts the number of times power was denied.
Absent Counter
Counts the number of times power was
removed because powered device dropout
was detected.
Invalid Signature
Counts the number of times an invalid signature
Counter
of a powered device was detected.
Following is a list of port status values:
Port is off – Underload disconnect detected
Port is off – Overload detected
Port is off – Short detected
Port is off - Invalid PD resistor signature detected
Port is on - Valid PD resistor signature detected
Port is off - Power was denied
Port is on - Valid capacitor signature detected
Port is off - Backoff state has occurred
Port is off - Class error has occurred
25.9

show power inline consumption

Use the show power inline consumption EXEC mode command to display
information about the inline power consumption for all interfaces or for a specific
interface.
Syntax
show power inline consumption
Parameters
Interface-id—Specifies an interface ID. The interface ID must be an Ethernet
port.
detailed—Displays information for non-present ports in addition to present
ports.
[interface-id| detailed ]