ToneOnPrimaryServiceDown
(OBi202 and OBi302 only)
Ringer
RingFrequency
RingVoltage
RingWaveform
3
InterleavedRing
Port Settings
OnHookTipRingVoltage
OffHookCurrentMax
Impedance
SP1 Service (code = sp1)
SP2 Service (code = sp2)
SP3 Service (code = sp3)
SP4 Service (code = sp4)
OBiTALK Service (code = pp1)
1
PSTN Line (code=li1)
Trunk Group 1 (code=tg1)
The OBi device process the parameter by substituting of
the occurrences of pli and (Mpli) in DigitMap,
OutboundCallRoute, and CallReturnDigitMaps with the
corresponding
code and (Mcode). For example, if PrimaryLine = PSTN
Line, then all occurrences of pli and (Mpli) will be
substituted internally with li1 and (Mli1) respectively
Select the tone to play in place dial tone when the service
corresponding to the Primary Line is out-of-service.
Choose from:
-
No Tone
-
Normal Dial Tone
-
SIT Tone 1
-
SIT Tone 2
-
SIT Tone 3
-
SIT Tone 4
Ringer frequency in Hz (14 - 68) to apply to the PHONE
port when ringing
Peak ringer voltage in volts (55 - 82) to apply to the
PHONE port when ringing
Ringer waveform to apply to the PHONE port when
ringing. Choices are Sinusoidal or Trapezoidal
When both phone ports are ringing, enabling this option
will cause the OBi to interleave the ring signal applied to
each port to reduce the chance of overloading the power
supply.
Tip/Ring Voltage when the attached phone is on hook (30
v to 52 v)
Maximum supported current (15 mA to 45 mA) when the
attached phone is off-hook
PHONE port impedance setting. Available choices are
(units in ohm if not specified):
-
600
-
900
-
270+(750||150 nF)
-
220+(820||120 nF)
-
370+(620||310 nF)
-
320+(1050||230 nF)
-
350+(1000||210 nF)
-
200+(680||100 nF)
-
600+2.16 uF
-
900+2.16 uF
Copyright 2010-2012 Obihai Technology, Inc.
Normal Dial Tone
20
70
Sinusoidal
No
46
20
600
129