Ignition Control - Honeywell Thor VM2 User Manual

Vehicle mount computer microsoft windows embedded standard operating systems
Hide thumbs Also See for Thor VM2:
Table of Contents

Advertisement

Ignition Control

Ignition wire must be connected and either Ignition Control power scheme (Ignition On or Ignition Off) can be selected. When
switched vehicle power is available the Thor VM2 ignition signal wire can be connected (less than 1mA over input voltage
range) to the switched circuit to allow the Thor VM2 to power on when the vehicle is switched on. When the vehicle is switched
off, more aggressive power management settings are enabled to preserve the vehicle battery charge.
Based on the status of the vehicle ignition, the Thor VM2 uses either the Ignition Control/Ignition On or Ignition Control/Ignition
Off power scheme timeouts.
1. Existing Circuitry on Vehicle
2. Forklift Battery
3. Main Switch
4. 10A Slow blow Fuse close to power source
5. Ignition
6. Red Wire (DC +)
7. Black Wire (DC -)
8. Green Wire (Ground)
9. Blue Wire (Ignition Signal)
10. Thor VM2 Computer in Quick Mount Smart Dock
11. COM1 or COM2 Connector on Dock
12. Circular Power Connector on Dock
13. If the vehicle chassis is not a suitable ground, connect
the Green wire to the negative terminal (-Vo) of the
power source.
3-9