7.8
AUXILIARY CONTROL OUTPUTS, CONTINUED
7.8.10

Network Auxiliary Output

Control output (011) is a network linked definition. It does not physically exist in this
video system's hardware configuration. It is declared to be a local representation of the
actual control output (47) defined in the video system node (02).
This could be any defined auxiliary control output within that video system. It's purpose
and function could be anything similar to the previous control output examples.
When control output (011) is activated and cleared the physical output (47) in node (02)
will be controlled. If the physical output (47) is changed by video system node (02)
itself, then the status carried against this local definition (011) will also update.
This means that macro sequences can interrogate the current status of any control
output defined in the system (local or cross network).
7.8.11

VideoBlox Configuration

Control output (12) is connected to I2C16 module of Videoblox device. It is connected to
Port 6 of MAXPRO-Net Server.